SCS 770066 EM Aware Monitor

Model: 770066

SCS 770066 EM Aware Monitor

Model: 770066

The monitor is compatible with the SCS static management program and monitors three key parameters that keep you aware of critical symptoms of ESD problems. These symptomps are ESD events, change in static voltage field, and ionizer performance.

The monitor is compatible with the SCS static management program and monitors three key parameters that keep you aware of critical symptoms of ESD problems. These symptomps are ESD events, change in static voltage field, and ionizer performance.

Sale Price $2067.31 USD
Regular Price $2349.22 USD
Availability 3 to 4 Weeks
Quantity

SCS 770066 Offers

This EM aware monitor has ESD event continuous monitor that detects and measures the unique waveform generated by ESD events.

Features

  • Ionizer Compatibility Range and Interchangeable Ionizer Antenna: Monitors ionizers with a balance (offset voltage) of ±40 V or better
  • ESD Event Continuous Monitor: Detects and measures the unique waveform generated by ESD events
  • Static Voltage Field Continuous Monitor: Measures the change in electrostatic field and alarms if the voltage exceeds a user-defined limit
  • Ethernet Connectivity: Provides network communication with Static Management Program (SMP). Data collected through SMP includes ESD event count and voltage, static voltage field and ionization discharge times and offset voltage (balance)
  • Optical Relay Terminal: Pairs with lights and buzzers for increased visibility
  • Comprehensive Diagnostics Tool: Identifies problematic environments and qualifies tools for handling ESD-sensitive devices
  • High Temperature Antenna Available: Use the CTC118-6FT to detect ESD events inside of surface mount ovens
  • 100-240 VAC Power Adapter with Interchangeable Plugs: Works with standard electrical systems in North America, United Kingdom, Japan, Asia and Europe
  • Assembled in the United States of America with Globally Sourced Materials

SCS 770066 Specifications

Power
Power Adapter Output: 7.5 VDC at 1.5 A
100 to 240 VAC Output Plug Polarization: Center positive
50 to 60 Hz Output Plug: 5.5 x 2.1 x 9.5 mm
ESD Event Monitor
Measurement Magnitude ESD event
ESD Event Threshold Default setting: 80 dBµV
Raw Input Signal 60 dBµV (1mV) to 134 dBµV (5.0 V)
Filtering Function ESD
Static Voltage Monitor
Measurement Static Voltage - Change of electrostatic field
Static Voltage Setting Range 12.5 V, 100 V, 250 V, 500 V, 1000 V, smart coefficient adjust
Output Ethernet
Ionizer Voltage and Decay Monitor
Compatible Ionizer Steady-State DC
Maximum Decay Time Reading 16 seconds maximum, typical
Maximum Decay Test Voltage ±5 V
Connectivity
Input SMA Connector for remote antenna
Outputs RJ45 connector for Ethernet output; 2-position terminal block for relay output
General Specifications
Alarm Buzzer
Display LCD
Dimensions (antenna not included) 3.17 x 2.25 x 1.26" (81 x 57 x 32 mm)
Weight 6.45 oz (183 g)
Click here for complete specifications on the SCS 770066

What's included with the SCS 770066

  • SCS 770066 EM Aware Monitor

Ask a question about SCS 770066 EM Aware Monitor

Customer Reviews for the SCS 770066

SCS 770066 Offers

This EM aware monitor has ESD event continuous monitor that detects and measures the unique waveform generated by ESD events.

Features

  • Ionizer Compatibility Range and Interchangeable Ionizer Antenna: Monitors ionizers with a balance (offset voltage) of ±40 V or better
  • ESD Event Continuous Monitor: Detects and measures the unique waveform generated by ESD events
  • Static Voltage Field Continuous Monitor: Measures the change in electrostatic field and alarms if the voltage exceeds a user-defined limit
  • Ethernet Connectivity: Provides network communication with Static Management Program (SMP). Data collected through SMP includes ESD event count and voltage, static voltage field and ionization discharge times and offset voltage (balance)
  • Optical Relay Terminal: Pairs with lights and buzzers for increased visibility
  • Comprehensive Diagnostics Tool: Identifies problematic environments and qualifies tools for handling ESD-sensitive devices
  • High Temperature Antenna Available: Use the CTC118-6FT to detect ESD events inside of surface mount ovens
  • 100-240 VAC Power Adapter with Interchangeable Plugs: Works with standard electrical systems in North America, United Kingdom, Japan, Asia and Europe
  • Assembled in the United States of America with Globally Sourced Materials

SCS 770066 Specifications

Power
Power Adapter Output: 7.5 VDC at 1.5 A
100 to 240 VAC Output Plug Polarization: Center positive
50 to 60 Hz Output Plug: 5.5 x 2.1 x 9.5 mm
ESD Event Monitor
Measurement Magnitude ESD event
ESD Event Threshold Default setting: 80 dBµV
Raw Input Signal 60 dBµV (1mV) to 134 dBµV (5.0 V)
Filtering Function ESD
Static Voltage Monitor
Measurement Static Voltage - Change of electrostatic field
Static Voltage Setting Range 12.5 V, 100 V, 250 V, 500 V, 1000 V, smart coefficient adjust
Output Ethernet
Ionizer Voltage and Decay Monitor
Compatible Ionizer Steady-State DC
Maximum Decay Time Reading 16 seconds maximum, typical
Maximum Decay Test Voltage ±5 V
Connectivity
Input SMA Connector for remote antenna
Outputs RJ45 connector for Ethernet output; 2-position terminal block for relay output
General Specifications
Alarm Buzzer
Display LCD
Dimensions (antenna not included) 3.17 x 2.25 x 1.26" (81 x 57 x 32 mm)
Weight 6.45 oz (183 g)