Teledyne LeCroy T3MIL50 D.C. Milli-Ohm Meter

Model: T3MIL50

Teledyne LeCroy T3MIL50 D.C. Milli-Ohm Meter

Model: T3MIL50

Suitable for various measuring applications, this D.C. milli-ohm meter features communication interfaces, faster measurements without sacrificing resolution, and a standard interface for control and communications. In addition, this meter has a 3.5" (88.9 mm) TFT LCD and performs quicker measurements without losing accuracy.

Suitable for various measuring applications, this D.C. milli-ohm meter features communication interfaces, faster measurements without sacrificing resolution, and a standard interface for control and communications. In addition, this meter has a 3.5" (88.9 mm) TFT LCD and performs quicker measurements without losing accuracy.

Your Price $1045.00 USD
Availability 15+ Weeks
Quantity

Teledyne LeCroy T3MIL50 Offers

Meet the requirements of low-resistance measurement applications with this reliable meter that provides four-wire measurements, temperature measurements, and temperature compensation functions. In addition, this meter has a 50,000-count measurement display and a sampling rate of 60 readings per second.

Features

  • 3.5" (88.9 mm) large TFT LCD display
  • Fast measurement rate of 60 readings per second with an accuracy of 0.05 %
  • Drive mode: : DC+, standby
  • Built-in temperature compensation measurement function
  • Standard interfaces: USB, RS-232C, HANDLER/SCAN/EXT I/O
  • Clear visibility of your measurement results
  • Faster measurements without losing accuracy
  • Suitable for various measuring applications
  • Accurate temperature measurements
  • Remote control your measurement
  • Reliable product gives peace of mind
  • 50,000 counts display
  • High accuracy of 0.05 %
  • 1 Amp test current, 0.1 μΩ resolution
  • Four wire resistance measurement
  • Temperature compensation measurement function
  • Delayed measurement
  • 20 sets of panel setting memory
  • Interface: USB Device, RS-232C, handler/scan/EXT I/O

Faster measurement without sacrificing resolution

Fast (60 readings per second) and slow (10 readings per second) measurement speeds. The measurement speed does not effect the measurement accuracy. The number of digits displayed remains the same irrespective of the measurement speed. The user can measure in fast mode without losing accuracy

Standard interface for control and communications

This D.C. milli-ohm meter provides a D-sub 25-pin combined interface to control the device for various functionalities such as Handler, Scan and EXT I/O. Handler function can be used for connecting the device to a sorting machine in a production environment. Scan and EXT I/O is useful when connecting to an external switch or for an external trigger control. T3MIL series also offers remote control and data retrieval through various interfaces such as RS 232C and USB.

Applications

  • Production testing of contact resistance of switches, relays, connectors, cables, and other low resistance devices
  • Production testing of various inductive components (coil, choke, and transformer winding etc.)
  • Testing of low value resistors, fuses, and heating elements
  • Winding resistance of motors, transformers, solenoids, and ballasts
  • Conductivity evaluation in product design
  • Incoming inspection and quality assurance testing

Teledyne LeCroy T3MIL50 Specifications

Display 50,000 counts
Sampling Rate Slow: 10 readings/s
Fast: 60 readings/s
Resistance Measurement Range:

5 mΩ:
Resolution: 0.1 μΩ
Test current: 1 A
Accuracy: ± (0.1 % reading + 0.2 % of range)

50 mΩ:
Resolution: 1 μΩ
Test current: 1 A
± (0.1 % reading + 0.02 % of range)
Accuracy: ± (0.1 % reading + 0.02 % of range)

500 mΩ:
Resolution: 10 μΩ
Test current: 100 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

5 Ω:
Resolution: 100 μΩ
Test current: 100 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

50 Ω:
Resolution: 1 mΩ
Test current: 10 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

500 Ω:
Resolution: 10 mΩ
Test current: 1 mA
Accuracy: ± (0.05 % reading + 0.008 % of range)

5 kΩ:
Resolution: 100 mΩ
Test current: 100μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

50 kΩ:
Resolution: 1 Ω
Test current: 100 μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

500 kΩ:
Resolution: 10 Ω
Test current: 10 μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

5 MΩ:
Resolution: 100 Ω
Test current: 1 μA
Accuracy: ± (0.2 % reading + 0.008 % of range)
Temperature Range: -58 ~ 751.82°F (-50 ~ 399.9°C)
Accuracy: -14 ~ 104°F: 0.3 % 32.9°F; Other: 0.3 % 34.7°F (-10 ~ 40°C: 0.3 % 0.5°C; Other: 0.3 % 1.5°C)
Resolution: 32.18°F (0.1°C)
Drive Mode DC+ only
Stanby: Yes
Interface USB: Standard
RS-232C: Standard
HANDLER/SCAN/EXT I/O: Standard
Display 3.5" (88.9 mm), 320 x 240 TFT LCD
Memory 20 sets for panel setting
Power Source AC 100 ~ 240 V, 50/60 Hz
Comsumption 25 VA (maximum)
Dimensions 8.78 x 4.01 x 11.14" (223 x 102 x 283 mm)
Weight Approximately 6.61 lbs (3 kg)
Click here for complete specifications on the Teledyne LeCroy T3MIL50

What's included with the Teledyne LeCroy T3MIL50

  • D.C. Milli-Ohm Meter
  • Test Lead
  • 3 x Power Cords
  • Three-Year Warranty

Ask a question about Teledyne LeCroy T3MIL50 D.C. Milli-Ohm Meter

Customer Reviews for the Teledyne LeCroy T3MIL50

Teledyne LeCroy T3MIL50 Offers

Meet the requirements of low-resistance measurement applications with this reliable meter that provides four-wire measurements, temperature measurements, and temperature compensation functions. In addition, this meter has a 50,000-count measurement display and a sampling rate of 60 readings per second.

Features

  • 3.5" (88.9 mm) large TFT LCD display
  • Fast measurement rate of 60 readings per second with an accuracy of 0.05 %
  • Drive mode: : DC+, standby
  • Built-in temperature compensation measurement function
  • Standard interfaces: USB, RS-232C, HANDLER/SCAN/EXT I/O
  • Clear visibility of your measurement results
  • Faster measurements without losing accuracy
  • Suitable for various measuring applications
  • Accurate temperature measurements
  • Remote control your measurement
  • Reliable product gives peace of mind
  • 50,000 counts display
  • High accuracy of 0.05 %
  • 1 Amp test current, 0.1 μΩ resolution
  • Four wire resistance measurement
  • Temperature compensation measurement function
  • Delayed measurement
  • 20 sets of panel setting memory
  • Interface: USB Device, RS-232C, handler/scan/EXT I/O

Faster measurement without sacrificing resolution

Fast (60 readings per second) and slow (10 readings per second) measurement speeds. The measurement speed does not effect the measurement accuracy. The number of digits displayed remains the same irrespective of the measurement speed. The user can measure in fast mode without losing accuracy

Standard interface for control and communications

This D.C. milli-ohm meter provides a D-sub 25-pin combined interface to control the device for various functionalities such as Handler, Scan and EXT I/O. Handler function can be used for connecting the device to a sorting machine in a production environment. Scan and EXT I/O is useful when connecting to an external switch or for an external trigger control. T3MIL series also offers remote control and data retrieval through various interfaces such as RS 232C and USB.

Applications

  • Production testing of contact resistance of switches, relays, connectors, cables, and other low resistance devices
  • Production testing of various inductive components (coil, choke, and transformer winding etc.)
  • Testing of low value resistors, fuses, and heating elements
  • Winding resistance of motors, transformers, solenoids, and ballasts
  • Conductivity evaluation in product design
  • Incoming inspection and quality assurance testing

Teledyne LeCroy T3MIL50 Specifications

Display 50,000 counts
Sampling Rate Slow: 10 readings/s
Fast: 60 readings/s
Resistance Measurement Range:

5 mΩ:
Resolution: 0.1 μΩ
Test current: 1 A
Accuracy: ± (0.1 % reading + 0.2 % of range)

50 mΩ:
Resolution: 1 μΩ
Test current: 1 A
± (0.1 % reading + 0.02 % of range)
Accuracy: ± (0.1 % reading + 0.02 % of range)

500 mΩ:
Resolution: 10 μΩ
Test current: 100 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

5 Ω:
Resolution: 100 μΩ
Test current: 100 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

50 Ω:
Resolution: 1 mΩ
Test current: 10 mA
Accuracy: ± (0.05 % reading + 0.02 % of range)

500 Ω:
Resolution: 10 mΩ
Test current: 1 mA
Accuracy: ± (0.05 % reading + 0.008 % of range)

5 kΩ:
Resolution: 100 mΩ
Test current: 100μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

50 kΩ:
Resolution: 1 Ω
Test current: 100 μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

500 kΩ:
Resolution: 10 Ω
Test current: 10 μA
Accuracy: ± (0.05 % reading + 0.008 % of range)

5 MΩ:
Resolution: 100 Ω
Test current: 1 μA
Accuracy: ± (0.2 % reading + 0.008 % of range)
Temperature Range: -58 ~ 751.82°F (-50 ~ 399.9°C)
Accuracy: -14 ~ 104°F: 0.3 % 32.9°F; Other: 0.3 % 34.7°F (-10 ~ 40°C: 0.3 % 0.5°C; Other: 0.3 % 1.5°C)
Resolution: 32.18°F (0.1°C)
Drive Mode DC+ only
Stanby: Yes
Interface USB: Standard
RS-232C: Standard
HANDLER/SCAN/EXT I/O: Standard
Display 3.5" (88.9 mm), 320 x 240 TFT LCD
Memory 20 sets for panel setting
Power Source AC 100 ~ 240 V, 50/60 Hz
Comsumption 25 VA (maximum)
Dimensions 8.78 x 4.01 x 11.14" (223 x 102 x 283 mm)
Weight Approximately 6.61 lbs (3 kg)
Click here for complete specifications on the Teledyne LeCroy T3MIL50

What's included with the Teledyne LeCroy T3MIL50

  • D.C. Milli-Ohm Meter
  • Test Lead
  • 3 x Power Cords
  • Three-Year Warranty

Ask a question about Teledyne LeCroy T3MIL50 D.C. Milli-Ohm Meter

Customer Reviews for the Teledyne LeCroy T3MIL50

More Teledyne LeCroy Products

Calibration Lab