Perform several functions with this docking and calibration station that is capable of charging, calibrating, and bump testing. Additionally, this station features a docking station with a one-cylinder input and automatically stores all records for future upload to a PC via a USB flash drive.
Perform several functions with this docking and calibration station that is capable of charging, calibrating, and bump testing. Additionally, this station features a docking station with a one-cylinder input and automatically stores all records for future upload to a PC via a USB flash drive.
An $85 hazmat/handling fee will automatically apply to all orders with this product.
Intended for use with the GX-3R (Pro) portable gas monitor, this calibration station has three separate gas inputs.
Features
Stand alone use
This calibration station is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor and it can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
PC-controlled use
Automate how you manage and service GX-3R (Pro) instruments by connecting this calibration station to a computer with a USB cable. With the docking station controller software, you can simultaneously calibrate, bump test, alarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from each instrument into one easy to manage location. These stations can be manifolded together to reduce the number of demand flow regulators gas cylinders required.
Input Power | AC Adapter with 100 to 240 V AC, 47 to 63 Hz, 0.4 A input and 5.99 V DC 2 A output provided as standard |
Environmental Conditions | Temperature: 32 to 104°F (0 to 40°C) Relative humdity: <95%, non-condensing For indoor use only |
Maximum Number of Records Saved | Stand alone: 200 calibrations, or 214 bump tests, or 469 alarm check records PC program controlled: Unlimited records |
5 Ports | 3 calibration gas 1 fresh air 1 exhaust |
Input Power | AC Adapter with 100 to 240 V AC, 47 to 63 Hz, 0.4 A input and 5.99 V DC 2 A output provided as standard |
Environmental Conditions | Temperature: 32 to 104°F (0 to 40°C) Relative humdity: <95%, non-condensing For indoor use only |
Maximum Number of Records Saved | Stand alone: 200 calibrations, or 214 bump tests, or 469 alarm check records PC program controlled: Unlimited records |
5 Ports | 3 calibration gas 1 fresh air 1 exhaust |