RIGOL RP1025D Specifications

Bandwidth X50 or X200 attenuation ratio: 25MHz (-3dB)
Attenuation Ratio X20, X50, X200
Accuracy ±2%
Input Voltage Range (DC + AC peak-peak value) X20: ≤140Vpp, about 50Vrms or DC X50: ≤350Vpp, about 125Vrms or DC X200: ≤1400Vpp, about 500Vrms or DC
Maximum Input Voltage Maximum differential voltage: 1400V (DC+AC peak-peak value) or 500Vrms Voltage to ground at the input terminal: 600Vrms
Input Impedance Differential: 4Mohm/1.2pF Single-ended and to ground: 2Mohm/2.3pF
Output Voltage ≤ °6.5V
Output Impedance 50ohm
Rise Time X50 or X200 attenuation ratio: 14ns X20 attenuation ratio: 23.4ns

What's included with the RIGOL RP1025D

  • RIGOL RP1025D High Voltage Differential Probe, DC-25 MHz, 1400 Vpp

Ask a question about RIGOL RP1025D High Voltage Differential Probe, DC-25 MHz, 1400 Vpp

Customer Reviews for the RIGOL RP1025D

RIGOL RP1025D Specifications

Bandwidth X50 or X200 attenuation ratio: 25MHz (-3dB)
Attenuation Ratio X20, X50, X200
Accuracy ±2%
Input Voltage Range (DC + AC peak-peak value) X20: ≤140Vpp, about 50Vrms or DC X50: ≤350Vpp, about 125Vrms or DC X200: ≤1400Vpp, about 500Vrms or DC
Maximum Input Voltage Maximum differential voltage: 1400V (DC+AC peak-peak value) or 500Vrms Voltage to ground at the input terminal: 600Vrms
Input Impedance Differential: 4Mohm/1.2pF Single-ended and to ground: 2Mohm/2.3pF
Output Voltage ≤ °6.5V
Output Impedance 50ohm
Rise Time X50 or X200 attenuation ratio: 14ns X20 attenuation ratio: 23.4ns

What's included with the RIGOL RP1025D