Ralston MF2S-QM-QM-PL 2-Port Manifold with quick-test connections, 5000 psi

Model: MF2S-QM-QM-PL

Ralston MF2S-QM-QM-PL 2-Port Manifold with quick-test connections, 5000 psi

Model: MF2S-QM-QM-PL

Ideally suited to test multiple pressure instruments at once, the stainless steel manifold provides up to 5000 psi (350 bar).

Ideally suited to test multiple pressure instruments at once, the stainless steel manifold provides up to 5000 psi (350 bar).

Your Price $548.00 USD
Availability 2 to 3 Weeks
Quantity

Ralston MF2S-QM-QM-PL Offers

Features

  • Calibrate multiple pressure gauges, transmitters or transducers at once
  • Vertically mounted ports are spaced far enough apart so larger gauges will fit easily
  • Quickly pressurize the system using a Ralston Quick-test hose
  • Switch between pressure connections on devices under test without a wrench
  • Compatible with all Ralston Quick-test NPT, BSP, Flare Gauge Adapters
  • Excellent for calibrating multiple pressure instruments in a thermal chamber
  • Second side connection can be used to daisy-chain multiple manifolds together

Calibration Manifold
With quick-test connections, the manifold provides one of the most economical way of performing static pressure calibrations in the field using nitrogen or other compressed gas.

  • Fine adjustment piston provides precise pressure control instead of trying to make adjustments with a pressure regulator and a needle valve
  • Soft-seated valves make filling and venting the system very precise
  • Compact design allows the manifold, gauge adapter and hoses to fit in the included nylon bag
  • Because pressure is controlled at the device under test, the nitrogen cylinder can be mounted on a truck
  • Low volume Quick-test hose, gauge adapter and process connection reduce gas usage and make nitrogen cylinders last longer
  • Made in U.S.A.

Nitrogen Calibration Sources
Self-contained unit provides a precise nitrogen source for calibrating differential and static pressure instrumentation using an external pressure calibrator

  • Proprietary pressure balanced fine adjustment piston allows for extremely precise, finger-tip control of pressure at 0.03 psi (2 mbar) or 3000 psi (210 bar) or any range in between.
  • Easily refillable nitrogen cylinder holds enough gas for multiple calibrations
  • Nylon bag to hold hose and fittings attached to inside of lid
  • Includes storage compartment in control panel for pressure reference test gauge
  • Low volume quick-test hose, gauge adapter and process connection can be attached to NPAK without thread sealant or a wrench
  • Onboard pressure gauges display cylinder and regulated pressure (accuracy +/-2.5% of full scale)

Ralston MF2S-QM-QM-PL Specifications

ConstructionPowder Coated Steel, Stainless Steel
Seal MaterialsBuna-N

What's included with the Ralston MF2S-QM-QM-PL

  • Ralston MF2S-QM-QM-PL 2-Port Manifold with quick-test connections, 5000 psi

Ask a question about Ralston MF2S-QM-QM-PL 2-Port Manifold with quick-test connections, 5000 psi

Customer Reviews for the Ralston MF2S-QM-QM-PL

Ralston MF2S-QM-QM-PL Offers

Features

  • Calibrate multiple pressure gauges, transmitters or transducers at once
  • Vertically mounted ports are spaced far enough apart so larger gauges will fit easily
  • Quickly pressurize the system using a Ralston Quick-test hose
  • Switch between pressure connections on devices under test without a wrench
  • Compatible with all Ralston Quick-test NPT, BSP, Flare Gauge Adapters
  • Excellent for calibrating multiple pressure instruments in a thermal chamber
  • Second side connection can be used to daisy-chain multiple manifolds together

Calibration Manifold
With quick-test connections, the manifold provides one of the most economical way of performing static pressure calibrations in the field using nitrogen or other compressed gas.

  • Fine adjustment piston provides precise pressure control instead of trying to make adjustments with a pressure regulator and a needle valve
  • Soft-seated valves make filling and venting the system very precise
  • Compact design allows the manifold, gauge adapter and hoses to fit in the included nylon bag
  • Because pressure is controlled at the device under test, the nitrogen cylinder can be mounted on a truck
  • Low volume Quick-test hose, gauge adapter and process connection reduce gas usage and make nitrogen cylinders last longer
  • Made in U.S.A.

Nitrogen Calibration Sources
Self-contained unit provides a precise nitrogen source for calibrating differential and static pressure instrumentation using an external pressure calibrator

  • Proprietary pressure balanced fine adjustment piston allows for extremely precise, finger-tip control of pressure at 0.03 psi (2 mbar) or 3000 psi (210 bar) or any range in between.
  • Easily refillable nitrogen cylinder holds enough gas for multiple calibrations
  • Nylon bag to hold hose and fittings attached to inside of lid
  • Includes storage compartment in control panel for pressure reference test gauge
  • Low volume quick-test hose, gauge adapter and process connection can be attached to NPAK without thread sealant or a wrench
  • Onboard pressure gauges display cylinder and regulated pressure (accuracy +/-2.5% of full scale)

Ralston MF2S-QM-QM-PL Specifications

ConstructionPowder Coated Steel, Stainless Steel