Capable of testing the inside wall hardness of rings without cutting the ring into pieces, this hardness testing machine features a maximum sample height of 9.8" (250 mm) and is 9.84 x 26.38 x 23.82" (250 x 667 x 621 mm). In addition, this hardness tester allows for a wide variety of hardness testing, including plastics.
Capable of testing the inside wall hardness of rings without cutting the ring into pieces, this hardness testing machine features a maximum sample height of 9.8" (250 mm) and is 9.84 x 26.38 x 23.82" (250 x 667 x 621 mm). In addition, this hardness tester allows for a wide variety of hardness testing, including plastics.
This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.
Work with an easy-to-use brake-start system that automatically begins testing when initial force is reached with this hardness testing machine. Capable of Rockwell, Rockwell Superficial, Rockwell testing of plastics (A and B), and light force Brinell hardness testing, this machine comes wit a touch screen control panel for displaying statistics and graphs. In addition, this machine has a curved correction function to help test round bars and spheres for hardness.
Features
Applications
Hardness Testing Methods | Rockwell/rockwell superficial/brinell/plastics hardness |
Initial Test Force (N) | 29.42 N (3 kgf), 98.07 N (10 kgf) |
Test Force (N) | Rockwell superficial: 147.1 N (15 kgf), 294.2 N (30 kgf), 441.3 N (45 kgf) Rockwell: 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf) Light force brinel: 61.29 (6.25 kgf), 98.07 (10 kgf), 153.2 (15.625 kgf), 245.2 (25 kgf), 294.2 (30 kgf), 306.5 (31.25 kgf), 612.9 (62.5 kgf), 980.7 (100 kgf), 1226 (125 kgf), 1839 (187.5 kgf) |
Test Force | Control: Automatic (load/hold/unload) Switching: Operated with the display unit Hold time: 1 to 120 seconds (selectable in units of 1 seconds) |
Table Up/Down Mechanism | Manual (automatic braking and load sequencing) |
Control Unit | Color touch-panel |
Maximum Table Loading | 45 lbs (20 kg) |
Ball Indenter | Tungsten carbide ball indenter |
Unit (Display Unit) | Inch/mm |
Display | Hardness value, test condition, go/no-go judgment result, statistical calculation result, X-R control chart, hardness conversion value Conversion function (HV, HK, HR [Rockwell hardness A, B, C, D, F, G/Rockwell superficial 15T, 30T, 45T, 15N, 30N, 45N], HS, HB, tensile strength) Go/no-go judgment function Continuous test function (for specimens with the same thickness) Cylindrical correction, spherical correction, offset correction, multi-point correction functions Statistical calculation function (maximum value, minimum value, mean value, standard deviation, upper limit value, lower limit value, go count, range, no-go count) Graph generation function (X-R control chart) |
External Data Output | RS-232C, digimatic, USB2.0 |
Language Support | Japanese, English, German, French, Italian, Spanish, Korean, Chinese (simplified characters/traditional characters), Turkish, Portuguese, Hungarian, Polish, Dutch and Czech |
Power Supply | AC120V |
Dimensions | Main unit: 9.84 x 26.38 x 23.82" (250 × 667 × 621 mm) Touch-panel display: (191 × 147 × 71 mm) Maximum specimen size: Height: 9.8" (250 mm) Depth: 5.9" (150 mm) Permissible inside diameter of a tube specimen: Minimum hole diameter: 1.38" (35 mm), when using the special indenter: .87" (22 mm) |
Weight | Approximately 132.28 lbs (60 kg) |
Hardness Testing Methods | Rockwell/rockwell superficial/brinell/plastics hardness |
Initial Test Force (N) | 29.42 N (3 kgf), 98.07 N (10 kgf) |
Test Force (N) | Rockwell superficial: 147.1 N (15 kgf), 294.2 N (30 kgf), 441.3 N (45 kgf) Rockwell: 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf) Light force brinel: 61.29 (6.25 kgf), 98.07 (10 kgf), 153.2 (15.625 kgf), 245.2 (25 kgf), 294.2 (30 kgf), 306.5 (31.25 kgf), 612.9 (62.5 kgf), 980.7 (100 kgf), 1226 (125 kgf), 1839 (187.5 kgf) |
Test Force | Control: Automatic (load/hold/unload) Switching: Operated with the display unit Hold time: 1 to 120 seconds (selectable in units of 1 seconds) |
Table Up/Down Mechanism | Manual (automatic braking and load sequencing) |
Control Unit | Color touch-panel |
Maximum Table Loading | 45 lbs (20 kg) |
Ball Indenter | Tungsten carbide ball indenter |
Unit (Display Unit) | Inch/mm |
Display | Hardness value, test condition, go/no-go judgment result, statistical calculation result, X-R control chart, hardness conversion value Conversion function (HV, HK, HR [Rockwell hardness A, B, C, D, F, G/Rockwell superficial 15T, 30T, 45T, 15N, 30N, 45N], HS, HB, tensile strength) Go/no-go judgment function Continuous test function (for specimens with the same thickness) Cylindrical correction, spherical correction, offset correction, multi-point correction functions Statistical calculation function (maximum value, minimum value, mean value, standard deviation, upper limit value, lower limit value, go count, range, no-go count) Graph generation function (X-R control chart) |
External Data Output | RS-232C, digimatic, USB2.0 |
Language Support | Japanese, English, German, French, Italian, Spanish, Korean, Chinese (simplified characters/traditional characters), Turkish, Portuguese, Hungarian, Polish, Dutch and Czech |
Power Supply | AC120V |
Dimensions | Main unit: 9.84 x 26.38 x 23.82" (250 × 667 × 621 mm) Touch-panel display: (191 × 147 × 71 mm) Maximum specimen size: Height: 9.8" (250 mm) Depth: 5.9" (150 mm) Permissible inside diameter of a tube specimen: Minimum hole diameter: 1.38" (35 mm), when using the special indenter: .87" (22 mm) |
Weight | Approximately 132.28 lbs (60 kg) |