Rental - Megger MIT515 5kV Megohmmeter

Model: MIT515-RENTAL

Rental - Megger MIT515 5kV Megohmmeter

Model: MIT515-RENTAL

Analog/Digital Resistance Tester Megohmmeter with a Lithium-Ion battery and a Max reading of 10 TOhms. CAT IV 600V.

Analog/Digital Resistance Tester Megohmmeter with a Lithium-Ion battery and a Max reading of 10 TOhms. CAT IV 600V.

Duration   day(s)
Your Price
63.00 USD
Quantity

Megger MIT515-RENTAL Offers

Features

  • Industry best guard terminal accuracy
  • Smaller size and lightweight allows easier transport and use without compromising performance
  • Compact and lightweight for easy transport and use
  • Auto IR, DAR and PI
  • Unique dual case design provides additional user protection
  • Lithium-ion battery - extended capacity, rapid charge
  • Advanced memory with time/date stamp
  • CATIV 600V safety rating on all terminals

Applications

  • Testing the Insulation of High or Low Voltage Electric Equipment
  • Generators
  • Motors
  • Transformers
  • Cables
  • Switchgear
  • High-Voltage Power Cables
  • High-Voltage Buses
  • Large Motor/Generator Windings
  • Line and Substation Transformers
  • Spot Tests
  • Stepvoltage Tests
  • Dielectric Discharge Tests
  • Ramp Tests
  • Dielectric Absorption Tests
  • Acceptance Testing at Installation to Check Conformance to Specifications
  • Routine Preventive/Predictive Maintenance Testing After Installation
  • QA Testing as Part of the Manufacturing Process
  • Diagnostic Testing to Isolate Faulty Components for Repair
  • Rotating Machinery
  • Insulation Resistance of Armature and Field Windings

Megger MIT515-RENTAL Specifications

Analog Insulation Range 100 kΩ to 10 TΩ
Digital Insulation Range 10 kΩ to 10 TΩ
Test Voltages 250 V, 500 V, 1000 V, 2500 V, and 5000 V
User Defined Test Voltages 100 V to 1 kV in 10 V Steps
1 kV to 5 kV in 25 V Steps
Accuracy (23°C) ±5% to 1 TΩ, ±20% to 10 TΩ
Voltage Output Accuracy (0 to 30°C) 4 to 0% ±10 V of nominal test voltage at 1 GΩ load
Voltmeter Range 30 to 660 V ac or dc, 50/60 Hz
Accuracy: ±3% ±3 V
Frequency Range: 45 Hz to 65 Hz
Short Circuit Current 3 mA Nominal, Max. Power on All Loads Outperforming Many
5 mA Testers
Insulation Alarm 100 kΩ to 1 GΩ
Current Measurement Range: 0.01 nA to 6 mA
Accuracy: ±5% ±0.2 nA at All Voltages
Capacitance Range Above 500 V 10 nF to 25 µF (Dependent on Measurement Voltage)
Accuracy (23°C): ±10% ±5 nF
Capacitor Charge <3 s per µF at 3 mA to 5 kV
Capacitor Discharge <250 ms/µF to Discharge from 5000 V to 50 V
Timer Range Up to 99 Minutes, 15 Seconds Minimum Setting
Memory Capacity 5 1/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests
Industry-Standard Tests IR, IR(t), DAR, PI
Interface USB Type B (Device)
Real Time Output USB, 1 Reading/Second (Voltage, Current and Resistance)
Interference Rejection 1 mA per 250 V up to a maximum of 3 mA
Guard Terminal 2% Error Guarding 500 kΩ Leakage with 100 mΩ Load
Voltage Input Range 85 to 265 V, 50/60 Hz, 60 VA
Battery Type Lithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003
Battery Life Typical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load
Battery Charge Time 2.5 Hours from Deep Discharge, 2 Hours Normal Discharge
30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW
Safety Meets the Requirements of IEC61010-1 CAT IV 600 V
Default Voltmeter Warns Operator of Applied Voltage Above 50 V
EMC Meets the requirements of IEC61326-1
Ingress Protection IP65 (Lid Closed)
IP40 (Lid Open)
Temperature Range Operating: -4 to 122°F (-20 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Humidity Range 90% RH @ 104°F (40°C)
Altitude 3000 m, CAT rating maintained >2000 m* (*test load connected)
Dimensions 12 x 11 x 7" (315 x 285 x 181 mm)
Weight 10 lb (4.5 kg)

What's included with the Megger MIT515-RENTAL

  • Megohmmeter
  • User Guide CD-ROM
  • Power Lead
  • 3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)

Ask a question about Rental - Megger MIT515 5kV Megohmmeter

Customer Reviews for the Megger MIT515-RENTAL

Megger MIT515-RENTAL Offers

Features

  • Industry best guard terminal accuracy
  • Smaller size and lightweight allows easier transport and use without compromising performance
  • Compact and lightweight for easy transport and use
  • Auto IR, DAR and PI
  • Unique dual case design provides additional user protection
  • Lithium-ion battery - extended capacity, rapid charge
  • Advanced memory with time/date stamp
  • CATIV 600V safety rating on all terminals

Applications

  • Testing the Insulation of High or Low Voltage Electric Equipment
  • Generators
  • Motors
  • Transformers
  • Cables
  • Switchgear
  • High-Voltage Power Cables
  • High-Voltage Buses
  • Large Motor/Generator Windings
  • Line and Substation Transformers
  • Spot Tests
  • Stepvoltage Tests
  • Dielectric Discharge Tests
  • Ramp Tests
  • Dielectric Absorption Tests
  • Acceptance Testing at Installation to Check Conformance to Specifications
  • Routine Preventive/Predictive Maintenance Testing After Installation
  • QA Testing as Part of the Manufacturing Process
  • Diagnostic Testing to Isolate Faulty Components for Repair
  • Rotating Machinery
  • Insulation Resistance of Armature and Field Windings

Megger MIT515-RENTAL Specifications

Analog Insulation Range 100 kΩ to 10 TΩ
Digital Insulation Range 10 kΩ to 10 TΩ
Test Voltages 250 V, 500 V, 1000 V, 2500 V, and 5000 V
User Defined Test Voltages 100 V to 1 kV in 10 V Steps
1 kV to 5 kV in 25 V Steps
Accuracy (23°C) ±5% to 1 TΩ, ±20% to 10 TΩ
Voltage Output Accuracy (0 to 30°C) 4 to 0% ±10 V of nominal test voltage at 1 GΩ load
Voltmeter Range 30 to 660 V ac or dc, 50/60 Hz
Accuracy: ±3% ±3 V
Frequency Range: 45 Hz to 65 Hz
Short Circuit Current 3 mA Nominal, Max. Power on All Loads Outperforming Many
5 mA Testers
Insulation Alarm 100 kΩ to 1 GΩ
Current Measurement Range: 0.01 nA to 6 mA
Accuracy: ±5% ±0.2 nA at All Voltages
Capacitance Range Above 500 V 10 nF to 25 µF (Dependent on Measurement Voltage)
Accuracy (23°C): ±10% ±5 nF
Capacitor Charge <3 s per µF at 3 mA to 5 kV
Capacitor Discharge <250 ms/µF to Discharge from 5000 V to 50 V
Timer Range Up to 99 Minutes, 15 Seconds Minimum Setting
Memory Capacity 5 1/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests
Industry-Standard Tests IR, IR(t), DAR, PI
Interface USB Type B (Device)
Real Time Output USB, 1 Reading/Second (Voltage, Current and Resistance)
Interference Rejection 1 mA per 250 V up to a maximum of 3 mA
Guard Terminal 2% Error Guarding 500 kΩ Leakage with 100 mΩ Load
Voltage Input Range 85 to 265 V, 50/60 Hz, 60 VA
Battery Type Lithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003
Battery Life Typical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load
Battery Charge Time 2.5 Hours from Deep Discharge, 2 Hours Normal Discharge
30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW
Safety Meets the Requirements of IEC61010-1 CAT IV 600 V
Default Voltmeter Warns Operator of Applied Voltage Above 50 V
EMC Meets the requirements of IEC61326-1
Ingress Protection IP65 (Lid Closed)
IP40 (Lid Open)
Temperature Range Operating: -4 to 122°F (-20 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Humidity Range 90% RH @ 104°F (40°C)
Altitude 3000 m, CAT rating maintained >2000 m* (*test load connected)
Dimensions 12 x 11 x 7" (315 x 285 x 181 mm)
Weight 10 lb (4.5 kg)

What's included with the Megger MIT515-RENTAL

  • Megohmmeter
  • User Guide CD-ROM
  • Power Lead
  • 3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)

Ask a question about Rental - Megger MIT515 5kV Megohmmeter

Customer Reviews for the Megger MIT515-RENTAL