Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V

Model: IMT100 | Order No: 1015-518

Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V

Model: IMT100 | Order No: 1015-518

Ideal for PV and industrial applications, this versatile hand-held industrial multi-tester is reliable for measuring insulation, low resistance testing, temperature, voltage, capacitance, and more. Moreover, this multi-tester includes 13 testing features, a guard terminal, diagnostic functions, and data storage management.

Ideal for PV and industrial applications, this versatile hand-held industrial multi-tester is reliable for measuring insulation, low resistance testing, temperature, voltage, capacitance, and more. Moreover, this multi-tester includes 13 testing features, a guard terminal, diagnostic functions, and data storage management.

Your Price $2800.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable In-House Calibration Certificate for your IMT100 - Multimeter Function

Traceable In-House Calibration Certificate for your IMT100 - Multimeter Function

Megger IMT100 Offers

The industrial multi tester is a versatile instrument with a complete suite of insulation and low resistance testing capabilities, plus continuity, inductance, capacitance, voltage, and temperature measurements. Additionally, the instrument can test insulation resistance from 100 Ω up to 200 GΩ, with test voltages of 50, 250, 500 V, 1 kV, and selectable variable voltage. The instrument includes a guard terminal, and supports several diagnostic insulation resistance functions including spot reading, polarisation index ratio, and timed insulation testing.

The multi tester comes with a unique four-wire digital low resistance function that includes a stable power supply that can deliver 200 mA in long circuits with a resistance range from 1 mΩ up to 10 Ω. This unit offers different test modes selectable through a soft keypad, including bidirectional, unidirectional, automatic, and continuous. The rotary switch and soft keypads are easy to operate, with or without gloved hands, and the instrument’s full colour graphic display makes it easy to select functions and take readings. 

The unit also has a supplied thermocouple (CAT III to 600 V) that enables you to test temperature and insulation resistance compensation. What’s more, the LRC function allows the IMT100 to automatically determine if the main element of the load is inductive, capacitive, or resistive, and displays the result on screen. It also gives you the ability to select each function and frequency of 120 to 1000 Hz.

Features

  • Complete suite of insulation resistance, exceptionally safe to use and ready for outdoor conditions
  • Full set of detachable test leads and guided lead set up diagrams
  • Ideal for testing photovoltaic installations
  • Full colour graphic display: Simple to understand and easy to use
  • Rotary dial control, soft keys and a full graphic display, simple and easy to use
  • DC voltage and polarity test, AC voltage, phase rotation and frequency, insulation resistance and surface leakage current detection
  • 4 wire low resistance bonding test, 2 wire continuity and diode test
  • User selectable insulation test terminal lockout voltage 25, 30, 50, 75 V (default is 50 V)
  • Full set of detachable test leads with interchangeable clips and probes for different applications, including PV connectors
  • Unique resistance testing capabilities with two, three and four terminals, including a guard connection to eliminate any surface leakage current
  • Insulation resistance tests: Resistance range 100 Ω up to 200 GΩ, supports PI, DAR, timed and temperature compensation
  • Stabilised insulation test voltage accurate to 0% 2% ±2 V, which provides a more accurate test voltage without the risk of over-voltage damage to circuits or components (the output voltage is maintained between 0 and 2% throughout the test range)
  • Voltmeter: Measures AC 10 mV up to 1000 V/DC 0 to 1000 V/True RMS (15 to 400 Hz)
  • Three phase supply and direction of rotation
  • Temperature: The supplied thermocouple CAT III 600 V, allows temperature test and insulation resistance compensation
  • Continuity (resistance) tests: Single automatic resistance range from 0.01 Ω to 1 MΩ
  • Automatic test current selection uses the preferred test current for the load resistance under test (200 mA up to 4 Ω)
  • Bi-directional tests option automatically reverses the current without reconnecting leads, while lead resistance compensation operates up to 10 Ω of resistance
  • Dedicated buzzer switch either ON, VISUAL or OFF, adjustable buzzer for maximum resistance limit (1 to 200 Ω in 12 steps) and buzzer sounds on test pass
  • DLRO four wire Kelvin low resistance: Automatic resistance range from 1 mΩ up to 10 Ω (selectable auto or manual test)
  • Bi-direction or single direction, bi-directional tests option automatically reverses the current without reconnecting leads: 200 mA test current
  • Motor direction of rotation: Tests the direction of rotation of a motor under test and displays the phase sequence on screen
  • Inductance, capacitance and resistance meter (LCR): Auto inductive, capacitive and resistive test, frequency selectable to 120 Hz or 1000 Hz
  • In AUTO mode, the multi tester automatically determines if the main element of the load is inductive, capacitive, or resistive and displays the result on screen and selectable inductance and capacitance test
  • Guard terminal: The guard terminal (G) is a third terminal on the connection panel that provides a return path for parallel leakage currents, which could otherwise create significant errors in the insulation measurement (for surface contamination of equipment or cables)
  • Storage and download of results: Test results can be downloaded to a USB mass storage device, which can be accessed by connecting to a PC or a laptop running PowerDB
  • Safety: The multi tester is designed to be exceptionally safe to use, with fast detecting circuitry reduces the likelihood of damage to the instrument if accidentally connected to live circuits or across phases
  • Live circuit detection and test inhibit on all measurements with user notification (except for direction of rotation measurements)
  • Detection and inhibit functions when the protection fuse has failed
  • Data storage and management: Data storage for up to 256 tests, which can be downloaded to a USB
  • Instrument software updates: Occasional information bulletins and software updates may be issued
  • Suitable for use on CAT III applications and supply voltages to 600 V up to 9843' (3000 m)
  • Meets the international requirements of IEC61010 and IEC61557, IEC62446 for PV testing and additional tests, UN EEC R100 regulation for electric vehicle
  • Rechargeable batteries with main charger kit
  • Environmental protection to IP54

Applications

  • Testing and fault-finding
  • Photovoltaic installations (domestic, industrial, utility scale)
  • Electric vehicles (HEV, PHEV, BEV)
  • Industrial and domestic installations
  • Rotating machinery

Megger IMT100 Specifications

Insulation Resistance Volts accuracy:
50 V: 10 GΩ ±2% ±2 digits ±4% per GΩ
100 V: 20 GΩ ±2% ±2 digits ±2% per GΩ
250 V: 50 GΩ ±2% ±2 digits ±0.8% per GΩ
500 V: 100 GΩ ±2% ±2 digits ±0.4% per GΩ
1000 V: 200 GΩ ±2% ±2 digits ±0.2% per GΩ
Polarisation Index (PI) 10 minutes/1 minute ratio
Dielectric Absorption Ratio (DAR) User configurable 15 or 30 seconds t1 start time with t2 fixed at 60 seconds
Guard Terminal Performance <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
Resolution: 0.1 kΩ
Short Circuit/Charge Current 2 mA 0% -50% (IEC61557-2)
Terminal Voltage Accuracy 0% 2% ±2 V
Test Current 1 mA at minimum pass value of insulation to a maximum of 2 mA
Operation Range 0.1 MΩ to 1 GΩ (IEC61557-2)
Leakage Current Display 0.1 uA resolution 10% (±3 digits)
Voltage Display ±3% ±2 digits ±0.5% of rated voltage
Continuity Measurement: 0.01 Ω to 1 MΩ
Accuracy:
±3% ±2 digits (0 to 99.9 Ω)
±5% ±2 digits (100 Ω to 500 kΩ)

Test current: 200 mA (0 mA 20 mA) (0.01 to 4 Ω)
Polarity: Single or dual (factory default)
Lead resistance: Null up to 10 Ω
Selectable current limit: 20 mA and 200 mA
Capacitance Range: 0.1 nF to 1 mF
Accuracy: ±5% ±2 digits (1 to 10 μF)
Voltmeter Range: DC: 0 to 1000 V
AC: 10 mV to 1000 V
TRMS sinusoidal (15 to 400 Hz)

Accuracy:
DC: ±2% ±2 digits (0 to 1000 V)
AC: ±2% ±2 digits (10 mV to 1000 V TRMS)

Frequency range: 15 to 400 Hz (50 mV to 1000 V)
Frequency resolution: 0.1 Hz
Frequency accuracy: ±0.5% ±1 digit
Diode test accuracy: ±2% ±2 digits
Display range: 0 to 3 V
Temperature Measurement and Compensation Thermocouple: Type T (Type K and Type J)
Thermocouple range: 4 to 392°F (-20 to 200°C)
Instrument range: 4 to 1832°F (-20 to 1000°C)
Instrument resolution: 0.18°F (0.1°C)
Instrument accuracy: ±1.8°F ±20 digits (±1°C ±20 digits)
(Basic accuracy stated assumes forward and reverse measurements)
DlRO Four Wire Kelvin Low Resistance Test current: 200 mA DC
Range: 1 mΩ to 10 Ω
Resolution: 0.01 mΩ
Accuracy: ±0.25% rdg. ±10 digits, accuracy stated includes forward and reverse measurements
Inductance Instrument accuracy:
Range: 1 H
Accuracy: ±(0.7% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 200 mH
Accuracy: ±(1% +(Lx/10000)% +5 digits)
Test frequency: 120 Hz
Accuracy: ±(0.7% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 20 mH
Accuracy: ±(2% +(Lx/10000) % +5 digits)
Test frequency: 120 Hz
Accuracy: ±(1.2% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 2 mH
Accuracy: ±(2% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz only
Results Storage Storage capacity: 256 test results (date/time stamped)
Data download: USB Type A (USB mass storage device)
Display Full LCD colour screen with user configurable backlight
Fuse x2 500 mA (FF) 1000 V 1.26 x 0.24" (32 x 6 mm) ceramic fuse, high break capacity HBC, 30 kA minimum. Glass fuses must not be installed
Language English, french, german and spanish
Power Battery: 6 x IEC LR6 1.5 V Alkaline (AA), IEC FR6 1.5 V Lithium (LiFeS2), IEC HR6 1.2 V NiMH (rechargeable option)
Battery life: 10 motors per (complete suite of tests at 100 V into 100 MO)
Battery charging: Mains battery charger kit
IEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 seconds testing on 25 seconds standby at 500 V into 0.5 MO
IEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 seconds testing on 25 standby on 1 Ω resistance
Safety Protection: IEC61010-1 CAT III 600 V
IP rating: IP54
EMC: Industrial IEC61326
Environmental Conditions Operating temperature range: 14 to 122°F (-10 to 50°C)
Storage temperature range: -13 to 122°F (-25 to 50°C)
Humidity: 90% RH at 104°F (40°C) maximum
Calibration temperature: 68°F (20°C)
Maximum altitude: 9843' (3000 m)
Temperature coefficient: <0.1% per °F and °C up to 1 GΩ
Dimensions 8.98 x 4.1 x 2.95" (228 x 105 x 75 mm)
Weight 2.02 lbs (0.93 kg)
Click here for complete specifications on the Megger IMT100

What's included with the Megger IMT100

  • Industrial Multi Tester
  • SP5 Remote Probe
  • Temperature Probe, T Type
  • Kelvin Clip Lead Set
  • Kelvin Probe Lead Set
  • Replaceable Kelvin Probe Pins
  • PV Test Lead Set Adaptors
  • Hook Strap Assembly
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V.

Megger 1012-069 Grabber Clip Lead Set, CAT III 100 V, CAT IV 600 V 1012-069
For use with the MTR105 rotating tester.




Megger 1012-066 Test Probe Set, long reach, CAT IV 600 V 1012-066
Comes equipped with a long reach and is rated CAT IV 600 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-065 Test Probe Set, long reach, CAT II 1000 V 1012-065
Comes equipped with a long reach and is CAT III 1000 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Ask a question about Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V

Customer Reviews for the Megger IMT100

Megger IMT100 Offers

The industrial multi tester is a versatile instrument with a complete suite of insulation and low resistance testing capabilities, plus continuity, inductance, capacitance, voltage, and temperature measurements. Additionally, the instrument can test insulation resistance from 100 Ω up to 200 GΩ, with test voltages of 50, 250, 500 V, 1 kV, and selectable variable voltage. The instrument includes a guard terminal, and supports several diagnostic insulation resistance functions including spot reading, polarisation index ratio, and timed insulation testing.

The multi tester comes with a unique four-wire digital low resistance function that includes a stable power supply that can deliver 200 mA in long circuits with a resistance range from 1 mΩ up to 10 Ω. This unit offers different test modes selectable through a soft keypad, including bidirectional, unidirectional, automatic, and continuous. The rotary switch and soft keypads are easy to operate, with or without gloved hands, and the instrument’s full colour graphic display makes it easy to select functions and take readings. 

The unit also has a supplied thermocouple (CAT III to 600 V) that enables you to test temperature and insulation resistance compensation. What’s more, the LRC function allows the IMT100 to automatically determine if the main element of the load is inductive, capacitive, or resistive, and displays the result on screen. It also gives you the ability to select each function and frequency of 120 to 1000 Hz.

Features

  • Complete suite of insulation resistance, exceptionally safe to use and ready for outdoor conditions
  • Full set of detachable test leads and guided lead set up diagrams
  • Ideal for testing photovoltaic installations
  • Full colour graphic display: Simple to understand and easy to use
  • Rotary dial control, soft keys and a full graphic display, simple and easy to use
  • DC voltage and polarity test, AC voltage, phase rotation and frequency, insulation resistance and surface leakage current detection
  • 4 wire low resistance bonding test, 2 wire continuity and diode test
  • User selectable insulation test terminal lockout voltage 25, 30, 50, 75 V (default is 50 V)
  • Full set of detachable test leads with interchangeable clips and probes for different applications, including PV connectors
  • Unique resistance testing capabilities with two, three and four terminals, including a guard connection to eliminate any surface leakage current
  • Insulation resistance tests: Resistance range 100 Ω up to 200 GΩ, supports PI, DAR, timed and temperature compensation
  • Stabilised insulation test voltage accurate to 0% 2% ±2 V, which provides a more accurate test voltage without the risk of over-voltage damage to circuits or components (the output voltage is maintained between 0 and 2% throughout the test range)
  • Voltmeter: Measures AC 10 mV up to 1000 V/DC 0 to 1000 V/True RMS (15 to 400 Hz)
  • Three phase supply and direction of rotation
  • Temperature: The supplied thermocouple CAT III 600 V, allows temperature test and insulation resistance compensation
  • Continuity (resistance) tests: Single automatic resistance range from 0.01 Ω to 1 MΩ
  • Automatic test current selection uses the preferred test current for the load resistance under test (200 mA up to 4 Ω)
  • Bi-directional tests option automatically reverses the current without reconnecting leads, while lead resistance compensation operates up to 10 Ω of resistance
  • Dedicated buzzer switch either ON, VISUAL or OFF, adjustable buzzer for maximum resistance limit (1 to 200 Ω in 12 steps) and buzzer sounds on test pass
  • DLRO four wire Kelvin low resistance: Automatic resistance range from 1 mΩ up to 10 Ω (selectable auto or manual test)
  • Bi-direction or single direction, bi-directional tests option automatically reverses the current without reconnecting leads: 200 mA test current
  • Motor direction of rotation: Tests the direction of rotation of a motor under test and displays the phase sequence on screen
  • Inductance, capacitance and resistance meter (LCR): Auto inductive, capacitive and resistive test, frequency selectable to 120 Hz or 1000 Hz
  • In AUTO mode, the multi tester automatically determines if the main element of the load is inductive, capacitive, or resistive and displays the result on screen and selectable inductance and capacitance test
  • Guard terminal: The guard terminal (G) is a third terminal on the connection panel that provides a return path for parallel leakage currents, which could otherwise create significant errors in the insulation measurement (for surface contamination of equipment or cables)
  • Storage and download of results: Test results can be downloaded to a USB mass storage device, which can be accessed by connecting to a PC or a laptop running PowerDB
  • Safety: The multi tester is designed to be exceptionally safe to use, with fast detecting circuitry reduces the likelihood of damage to the instrument if accidentally connected to live circuits or across phases
  • Live circuit detection and test inhibit on all measurements with user notification (except for direction of rotation measurements)
  • Detection and inhibit functions when the protection fuse has failed
  • Data storage and management: Data storage for up to 256 tests, which can be downloaded to a USB
  • Instrument software updates: Occasional information bulletins and software updates may be issued
  • Suitable for use on CAT III applications and supply voltages to 600 V up to 9843' (3000 m)
  • Meets the international requirements of IEC61010 and IEC61557, IEC62446 for PV testing and additional tests, UN EEC R100 regulation for electric vehicle
  • Rechargeable batteries with main charger kit
  • Environmental protection to IP54

Applications

  • Testing and fault-finding
  • Photovoltaic installations (domestic, industrial, utility scale)
  • Electric vehicles (HEV, PHEV, BEV)
  • Industrial and domestic installations
  • Rotating machinery

Megger IMT100 Specifications

Insulation Resistance Volts accuracy:
50 V: 10 GΩ ±2% ±2 digits ±4% per GΩ
100 V: 20 GΩ ±2% ±2 digits ±2% per GΩ
250 V: 50 GΩ ±2% ±2 digits ±0.8% per GΩ
500 V: 100 GΩ ±2% ±2 digits ±0.4% per GΩ
1000 V: 200 GΩ ±2% ±2 digits ±0.2% per GΩ
Polarisation Index (PI) 10 minutes/1 minute ratio
Dielectric Absorption Ratio (DAR) User configurable 15 or 30 seconds t1 start time with t2 fixed at 60 seconds
Guard Terminal Performance <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
Resolution: 0.1 kΩ
Short Circuit/Charge Current 2 mA 0% -50% (IEC61557-2)
Terminal Voltage Accuracy 0% 2% ±2 V
Test Current 1 mA at minimum pass value of insulation to a maximum of 2 mA
Operation Range 0.1 MΩ to 1 GΩ (IEC61557-2)
Leakage Current Display 0.1 uA resolution 10% (±3 digits)
Voltage Display ±3% ±2 digits ±0.5% of rated voltage
Continuity Measurement: 0.01 Ω to 1 MΩ
Accuracy:
±3% ±2 digits (0 to 99.9 Ω)
±5% ±2 digits (100 Ω to 500 kΩ)

Test current: 200 mA (0 mA 20 mA) (0.01 to 4 Ω)
Polarity: Single or dual (factory default)
Lead resistance: Null up to 10 Ω
Selectable current limit: 20 mA and 200 mA
Capacitance Range: 0.1 nF to 1 mF
Accuracy: ±5% ±2 digits (1 to 10 μF)
Voltmeter Range: DC: 0 to 1000 V
AC: 10 mV to 1000 V
TRMS sinusoidal (15 to 400 Hz)

Accuracy:
DC: ±2% ±2 digits (0 to 1000 V)
AC: ±2% ±2 digits (10 mV to 1000 V TRMS)

Frequency range: 15 to 400 Hz (50 mV to 1000 V)
Frequency resolution: 0.1 Hz
Frequency accuracy: ±0.5% ±1 digit
Diode test accuracy: ±2% ±2 digits
Display range: 0 to 3 V
Temperature Measurement and Compensation Thermocouple: Type T (Type K and Type J)
Thermocouple range: 4 to 392°F (-20 to 200°C)
Instrument range: 4 to 1832°F (-20 to 1000°C)
Instrument resolution: 0.18°F (0.1°C)
Instrument accuracy: ±1.8°F ±20 digits (±1°C ±20 digits)
(Basic accuracy stated assumes forward and reverse measurements)
DlRO Four Wire Kelvin Low Resistance Test current: 200 mA DC
Range: 1 mΩ to 10 Ω
Resolution: 0.01 mΩ
Accuracy: ±0.25% rdg. ±10 digits, accuracy stated includes forward and reverse measurements
Inductance Instrument accuracy:
Range: 1 H
Accuracy: ±(0.7% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 200 mH
Accuracy: ±(1% +(Lx/10000)% +5 digits)
Test frequency: 120 Hz
Accuracy: ±(0.7% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 20 mH
Accuracy: ±(2% +(Lx/10000) % +5 digits)
Test frequency: 120 Hz
Accuracy: ±(1.2% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz

Range: 2 mH
Accuracy: ±(2% +(Lx/10000)% +5 digits)
Test frequency: 1 kHz only
Results Storage Storage capacity: 256 test results (date/time stamped)
Data download: USB Type A (USB mass storage device)
Display Full LCD colour screen with user configurable backlight
Fuse x2 500 mA (FF) 1000 V 1.26 x 0.24" (32 x 6 mm) ceramic fuse, high break capacity HBC, 30 kA minimum. Glass fuses must not be installed
Language English, french, german and spanish
Power Battery: 6 x IEC LR6 1.5 V Alkaline (AA), IEC FR6 1.5 V Lithium (LiFeS2), IEC HR6 1.2 V NiMH (rechargeable option)
Battery life: 10 motors per (complete suite of tests at 100 V into 100 MO)
Battery charging: Mains battery charger kit
IEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 seconds testing on 25 seconds standby at 500 V into 0.5 MO
IEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 seconds testing on 25 standby on 1 Ω resistance
Safety Protection: IEC61010-1 CAT III 600 V
IP rating: IP54
EMC: Industrial IEC61326
Environmental Conditions Operating temperature range: 14 to 122°F (-10 to 50°C)
Storage temperature range: -13 to 122°F (-25 to 50°C)
Humidity: 90% RH at 104°F (40°C) maximum
Calibration temperature: 68°F (20°C)
Maximum altitude: 9843' (3000 m)
Temperature coefficient: <0.1% per °F and °C up to 1 GΩ
Dimensions 8.98 x 4.1 x 2.95" (228 x 105 x 75 mm)
Weight 2.02 lbs (0.93 kg)
Click here for complete specifications on the Megger IMT100

What's included with the Megger IMT100

  • Industrial Multi Tester
  • SP5 Remote Probe
  • Temperature Probe, T Type
  • Kelvin Clip Lead Set
  • Kelvin Probe Lead Set
  • Replaceable Kelvin Probe Pins
  • PV Test Lead Set Adaptors
  • Hook Strap Assembly
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V.

Megger 1012-069 Grabber Clip Lead Set, CAT III 100 V, CAT IV 600 V 1012-069
For use with the MTR105 rotating tester.




Megger 1012-066 Test Probe Set, long reach, CAT IV 600 V 1012-066
Comes equipped with a long reach and is rated CAT IV 600 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-065 Test Probe Set, long reach, CAT II 1000 V 1012-065
Comes equipped with a long reach and is CAT III 1000 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Ask a question about Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V

Customer Reviews for the Megger IMT100

More Megger Products

Calibration Lab