Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3

Model: 1005-262 | UPC: 5036175229958

Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3

Model: 1005-262 | UPC: 5036175229958

The medium insulated clips are to be used to with all MIT and S1 15kV instruments. The design of the lead sets is intended to facilitate connection to a variety of de-energized systems for the purpose of making insulation resistance measurements.

The medium insulated clips are to be used to with all MIT and S1 15kV instruments. The design of the lead sets is intended to facilitate connection to a variety of de-energized systems for the purpose of making insulation resistance measurements.

Sale Price $202.73 USD
Regular Price $255.00 USD
Availability 3 in Stock
Quantity

Megger 1005-262 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces but where space us at a premium. The insulation is designed only to protect the user from the output of Megger 5 kV, 10 kV and 15 kV insulation testers.

The clips cannon in any circumstances to relied on to protect the user from live systems above 600 V a.c in a CAT IV environment, or 1000 V a.c in a CAT III environment.

Megger 1005-262 Specifications

Dimensions 58 (L) X 25 (closed) mm
Jaw opening 20 mm dia max (clip)
Number in set 2
Double insulation rating 1 kV d.c
CAT rating 600 V a.c CAT III
Lead length 10 m
Insulation rating 1 kV d.c
Cable type Flexible double insulation silicon
Click here for complete specifications on the Megger 1005-262

What's included with the Megger 1005-262

  • Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3

Ask a question about Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3

Customer Reviews for the Megger 1005-262

Megger 1005-262 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces but where space us at a premium. The insulation is designed only to protect the user from the output of Megger 5 kV, 10 kV and 15 kV insulation testers.

The clips cannon in any circumstances to relied on to protect the user from live systems above 600 V a.c in a CAT IV environment, or 1000 V a.c in a CAT III environment.

Megger 1005-262 Specifications

Dimensions 58 (L) X 25 (closed) mm
Jaw opening 20 mm dia max (clip)
Number in set 2
Double insulation rating 1 kV d.c
CAT rating 600 V a.c CAT III
Lead length 10 m
Insulation rating 1 kV d.c
Cable type Flexible double insulation silicon
Click here for complete specifications on the Megger 1005-262

What's included with the Megger 1005-262

  • Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3

Ask a question about Megger 1005-262 HV Test Lead Set, 3m, 15kV, Medium Insulated Clips, Set of 3