Kyoritsu 5410 RCD Tester

Model: 5410 | Order No: KEW5410

Kyoritsu 5410 RCD Tester

Model: 5410 | Order No: KEW5410

Simple to use. Features an operating voltage up to 400V. Can measure both RCD Trip Time and Trip Out Current.

Simple to use. Features an operating voltage up to 400V. Can measure both RCD Trip Time and Trip Out Current.

Sale Price $660.00 USD
Regular Price $750.00 USD
Availability 1 to 2 Weeks
Quantity

Kyoritsu 5410 Offers

  • Measurement of RCD Trip Time
    Conduct tests on rated residual non-operating currents at x 1/2 range, measuring RCD trip time at x1 and x5 Ranges.
  • Measurement of Trip Out Currents
    Performs measurements of trip out currents by varying current automatically.
  • Remote Test
    Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
  • Voltage Measurement
    Carrying out a constant measurement of voltage in the stand-by mode at each Range.
  • Auto-Detection of Contact Voltage
    Detects voltage to earth via Earth Electrodes or Protective Conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
  • Dust and Water-Proof
    Construction designed to IEC 60529 IP54 standards.
  • Backlight
    Facilitating working at dimly illuminated locations.

Kyoritsu 5410 Specifications

Range x5
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100mA
Measuring Range Testing Time: 200ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) 2 to 8%dgt
Range x1
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range Testing Time: 2000ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) 2 to 8%dgt
Range x1/2
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range Testing Time: 2000ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) -8 to -2%dgt
Range AUTO RAMP (mA)
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range 40 to 110% of lΔn
(goes up by 5%)
Testing Time: 300ms × 15steps
Accuracy (Trip Time & Test Current) Test Current at each step
-4% to 4%
Click here for complete specifications on the Kyoritsu 5410

What's included with the Kyoritsu 5410

  • RCD Tester
  • 7128A Test Leads
  • 7129A Test Lead with Alligator Clip
  • 2 x 8017 Long Pin
  • Shoulder Strap
  • 8 x AA Batteries
  • Instruction Manual
  • Cord Case

Ask a question about Kyoritsu 5410 RCD Tester

Customer Reviews for the Kyoritsu 5410

Kyoritsu 5410 Offers

  • Measurement of RCD Trip Time
    Conduct tests on rated residual non-operating currents at x 1/2 range, measuring RCD trip time at x1 and x5 Ranges.
  • Measurement of Trip Out Currents
    Performs measurements of trip out currents by varying current automatically.
  • Remote Test
    Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
  • Voltage Measurement
    Carrying out a constant measurement of voltage in the stand-by mode at each Range.
  • Auto-Detection of Contact Voltage
    Detects voltage to earth via Earth Electrodes or Protective Conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
  • Dust and Water-Proof
    Construction designed to IEC 60529 IP54 standards.
  • Backlight
    Facilitating working at dimly illuminated locations.

Kyoritsu 5410 Specifications

Range x5
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100mA
Measuring Range Testing Time: 200ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) 2 to 8%dgt
Range x1
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range Testing Time: 2000ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) 2 to 8%dgt
Range x1/2
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range Testing Time: 2000ms
Accuracy (Trip Time) ±1%rdg±3dgt
Accuracy (Test Current) -8 to -2%dgt
Range AUTO RAMP (mA)
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100/200/500mA
Measuring Range 40 to 110% of lΔn
(goes up by 5%)
Testing Time: 300ms × 15steps
Accuracy (Trip Time & Test Current) Test Current at each step
-4% to 4%
Click here for complete specifications on the Kyoritsu 5410

What's included with the Kyoritsu 5410

  • RCD Tester
  • 7128A Test Leads
  • 7129A Test Lead with Alligator Clip
  • 2 x 8017 Long Pin
  • Shoulder Strap
  • 8 x AA Batteries
  • Instruction Manual
  • Cord Case

Ask a question about Kyoritsu 5410 RCD Tester

Customer Reviews for the Kyoritsu 5410

More Kyoritsu Products

Calibration Lab