Highly compact and easy to use, this insulation and continuity tester is designed to strict IEC61010-1 safety standards and has an IP54 protection rating. In addition, it is ideally suited for more arduous environments and offers three insulation test ranges, a three Ω continuity range, and a 500 Ω resistance range.
Highly compact and easy to use, this insulation and continuity tester is designed to strict IEC61010-1 safety standards and has an IP54 protection rating. In addition, it is ideally suited for more arduous environments and offers three insulation test ranges, a three Ω continuity range, and a 500 Ω resistance range.
Features
Insulation Resistance | |
Test Voltage | 250/500/1000 V |
Measuring Range (Mid-Scale Value) | 100/200/400 MΩ (1/2/4 MΩ) |
Output Voltage on Open Circuit | Rated test voltage + 20%, -0% 4 to 9 V DC |
Nominal Current | 1 mA DC minimum |
Output Short Circuit Current | 1 to 2 mA DC |
Measuring Current | 200 mA DC min |
Accuracy | 0.1 to 10/0.2 to 20/0.4 to 40 MΩ (Accuracy guaranteed ranges) ±5% of indicated value |
Continuity | |
Measuring Ranges (Mid-Scale Value) | 3/500 Ω (1.5/20 Ω) |
Output Voltage on Open Circuit | 4.1 V DC approximately |
Measuring Current | 210 mA DC minimum |
Accuracy | ±1.5% of scale length |
AC Voltage | |
AC Voltage | 0 to 600 V AC |
Accuracy | ±5% of scale length |
General Specifications | |
Safety Standard | IEC 61010-1 CAT III 600 V Pollution °2 IEC 61010-2-031 IEC 61557-1/2/4 |
IP Rating | IEC 60529-IP54 |
EMC Standard | IEC 61326-1 |
Power Source | R6 (AA) (1.5 V) × 6 |
Dimensions | 4.17 x 6.3 x 2.83" (106 × 160 × 72 mm) |
Weight | 1.23 lbs (560 g) approximately |
Insulation Resistance | |
Test Voltage | 250/500/1000 V |
Measuring Range (Mid-Scale Value) | 100/200/400 MΩ (1/2/4 MΩ) |
Output Voltage on Open Circuit | Rated test voltage + 20%, -0% 4 to 9 V DC |
Nominal Current | 1 mA DC minimum |
Output Short Circuit Current | 1 to 2 mA DC |
Measuring Current | 200 mA DC min |
Accuracy | 0.1 to 10/0.2 to 20/0.4 to 40 MΩ (Accuracy guaranteed ranges) ±5% of indicated value |
Continuity | |
Measuring Ranges (Mid-Scale Value) | 3/500 Ω (1.5/20 Ω) |
Output Voltage on Open Circuit | 4.1 V DC approximately |
Measuring Current | 210 mA DC minimum |
Accuracy | ±1.5% of scale length |
AC Voltage | |
AC Voltage | 0 to 600 V AC |
Accuracy | ±5% of scale length |
General Specifications | |
Safety Standard | IEC 61010-1 CAT III 600 V Pollution °2 IEC 61010-2-031 IEC 61557-1/2/4 |
IP Rating | IEC 60529-IP54 |
EMC Standard | IEC 61326-1 |
Power Source | R6 (AA) (1.5 V) × 6 |
Dimensions | 4.17 x 6.3 x 2.83" (106 × 160 × 72 mm) |
Weight | 1.23 lbs (560 g) approximately |