The airflow measurements for supply and return are highly precise. Changing the hoods allows for easy sampling of air from ducts of any size. This unit is lightweight and simple to handle. The full color screen can be adjusted to the perfect viewing angle at any height. Model 6720 includes a detachable handheld micromanometer with Bluetooth wireless technology.
The airflow measurements for supply and return are highly precise. Changing the hoods allows for easy sampling of air from ducts of any size. This unit is lightweight and simple to handle. The full color screen can be adjusted to the perfect viewing angle at any height. Model 6720 includes a detachable handheld micromanometer with Bluetooth wireless technology.
The Kanomax 6720 TABmaster airflow capture hood combines a lightweight build with robustness, allowing for seamless and productive airflow measurements. It is outfitted with a comfortable handle for effortless positioning and an easy-to-use interface for straightforward operation. The device provides immediate and legible readings, conveniently showcased on a spacious digital display, enabling swift analysis of airflow information.The 6720 is an ideal tool for precise supply and return airflow measurements, offering flexibility and convenience with its interchangeable hood and detachable digital manometer. This multifunctional instrument simultaneously measures and displays air flow, temperature, and humidity, while also indicating the direction and velocity of the airflow. Additionally, the removable handheld micromanometer provides accurate airflow and pressure readings, making it a versatile addition to your measurement toolkit.
Features
Applications
Airflow Range | 23 to 2531 CFM (40 to 4300 m3/h) |
Differential Pressure Accuracy | Readings +/-1.5% | +/-25Pa |
Humidity resolution | .1%RH |
Airflow Accuracy | +/- 3% of Reading +/-8m3/h (>85m3/h) |
Differential Pressure resolution | 0.001Pa |
Airflow resoltuion | 1 m3/h |
Temperature Range | 32 to 140°F )0 to 60°C |
Velocity Range | 0.15~40m/s (Pitot Tube), 015~15m/s (Velocity Grid) |
Temperature Accuracy | +/-0.5°C |
Velocity Accuracy | reading +/-3% +/- 0.05m/s | 025m/s |
Temperature resolution | 0.1°C |
Velocity resoltuion | 0.01m/s |
Humidity Range | 0 to 100%RH |
Differential Pressure Range | -2500~2500pa |
Humidity Accuracy | +/-3.0%RH (10 to 90%RH) |
Airflow Range | 23 to 2531 CFM (40 to 4300 m3/h) |
Differential Pressure Accuracy | Readings +/-1.5% | +/-25Pa |
Humidity resolution | .1%RH |
Airflow Accuracy | +/- 3% of Reading +/-8m3/h (>85m3/h) |
Differential Pressure resolution | 0.001Pa |
Airflow resoltuion | 1 m3/h |
Temperature Range | 32 to 140°F )0 to 60°C |
Velocity Range | 0.15~40m/s (Pitot Tube), 015~15m/s (Velocity Grid) |
Temperature Accuracy | +/-0.5°C |
Velocity Accuracy | reading +/-3% +/- 0.05m/s | 025m/s |
Temperature resolution | 0.1°C |
Velocity resoltuion | 0.01m/s |
Humidity Range | 0 to 100%RH |
Differential Pressure Range | -2500~2500pa |
Humidity Accuracy | +/-3.0%RH (10 to 90%RH) |