Safely measure the resistance of super-small electronic components with this meter. The meter delivers high-speed results from 100mΩ to 1,000Ω.
Safely measure the resistance of super-small electronic components with this meter. The meter delivers high-speed results from 100mΩ to 1,000Ω.
Measure DC resistance over a vast range with this Hioki RM3542-50 Resistance Meter. The meter is built to gauge resistance from 100 mΩ to 1,000 Ω at high speeds and with precision. A contact improvement function allows you to safely evaluate super-small electronic components without rush current.
Features
Resistance Range | 100 mΩ to 100 MΩ range in 16 steps (low power off), 1,000 mΩ to 1,000 Ω range in 6 steps (low power on) |
Measurement Accuracy | ±0.015% of reading ± 0.002% full scale (slow mode, at 100 mΩ range), ±0.006% of reading ±0.001% full scale (slow mode, at 1,000 Ω range) |
Testing Current | 100 mA DC (100 mΩ range) to 100 nA DC (100 MΩ range) |
Open-Terminal Voltage | 20 VDC maximum, 10 VDC (with applied voltage limit function enabled) |
Sampling Rate | Fast, medium, slow, 3 settings |
Measurement Times | Fast: 0.9 ms, medium: 3.6 ms, slow: 17 ms (at 100 Ω/1,000 Ω ranges, with low power off) |
Other Functions | Comparator, delay, applied voltage limit, scaling, OVC (offset voltage compensation), measurement fault detection, probe short-circuit detection, improve contact, auto-memory, statistical calculations, settings monitor, retry, trigger |
Interface | RS-232C, printer |
External I/O Functions | Trigger, hold input, comparator output, settings monitor terminal |
Power Supply | 100 to 240 VAC, 50/60 Hz, 30 VA maximum |
Integration Time | 0.1 to 100 ms, 1 to 5 PLC (Power Line Cycles) at 50 Hz, 1 to 6 PLC at 60 Hz |
Product Length | 11.81" (300 mm) |
Product Width | 10.24" (260 mm) |
Product Height | 3.46" (88 mm) |
Product Weight | 102.3 oz (2.9 kg) |
Manufacturer Warranty | 3-year limited |
Resistance Range | 100 mΩ to 100 MΩ range in 16 steps (low power off), 1,000 mΩ to 1,000 Ω range in 6 steps (low power on) |
Measurement Accuracy | ±0.015% of reading ± 0.002% full scale (slow mode, at 100 mΩ range), ±0.006% of reading ±0.001% full scale (slow mode, at 1,000 Ω range) |
Testing Current | 100 mA DC (100 mΩ range) to 100 nA DC (100 MΩ range) |
Open-Terminal Voltage | 20 VDC maximum, 10 VDC (with applied voltage limit function enabled) |
Sampling Rate | Fast, medium, slow, 3 settings |
Measurement Times | Fast: 0.9 ms, medium: 3.6 ms, slow: 17 ms (at 100 Ω/1,000 Ω ranges, with low power off) |
Other Functions | Comparator, delay, applied voltage limit, scaling, OVC (offset voltage compensation), measurement fault detection, probe short-circuit detection, improve contact, auto-memory, statistical calculations, settings monitor, retry, trigger |
Interface | RS-232C, printer |
External I/O Functions | Trigger, hold input, comparator output, settings monitor terminal |
Power Supply | 100 to 240 VAC, 50/60 Hz, 30 VA maximum |
Integration Time | 0.1 to 100 ms, 1 to 5 PLC (Power Line Cycles) at 50 Hz, 1 to 6 PLC at 60 Hz |
Product Length | 11.81" (300 mm) |
Product Width | 10.24" (260 mm) |
Product Height | 3.46" (88 mm) |
Product Weight | 102.3 oz (2.9 kg) |
Manufacturer Warranty | 3-year limited |