A Standard for quality testing of lithium-ion batteries, the battery hi-tester features high-precision measurement capabilities. Augmented with improved tolerances for path resistance to keep measurement errors from halting automatic testing lines and significantly improved resistance to static electricity.
A Standard for quality testing of lithium-ion batteries, the battery hi-tester features high-precision measurement capabilities. Augmented with improved tolerances for path resistance to keep measurement errors from halting automatic testing lines and significantly improved resistance to static electricity.
Fully automated production line testing of large cells for xEVs or mid-sized packs of up to 100 V.
Features
Applications
Resistance Measurement Ranges | 3 mΩ(max. display: 3.1000 mΩ, resolution: 0.1 µΩ, measurement current: 100 mA) 30 mΩ(max. display: 31.000 mΩ, resolution: 1 µΩ, measurement current: 100 mA) 300 mΩ(max. display: 310.00 mΩ, resolution: 10 µΩ, measurement current: 10 mA) 3 Ω(max. display: 3.1000 Ω, resolution: 100 µΩ, measurement current: 1 mA) 30 Ω(max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 µA) 300 Ω(max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 µA) 3 kΩ(max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 µA) |
|||
Basic Accuracy | ±0.5% rdg ±10 dgt(3 mΩ range), ±0.5% rdg ±5 dgt(30 mΩ range or more) | |||
Measurement Frequency | 1 kHz ±0.2 Hz | |||
Measurement Method | AC four-terminal method | |||
Voltage Measurement Ranges | 6 V(max. display: 6.00000 V, resolution: 10 µV) 60 V(max. display: 60.0000 V, resolution: 100 µV) 100 V(max. display: 100.000 V, resolution: 1 mV) |
|||
Response Time | 10 ms | |||
Functions | Contact check, zero adjustment (±1000 counts), pulse measurement, comparator (Hi/ IN/ Lo), statistical calculations (max. 30,000), delay, average, panel saving/loading, memory storage, LabVIEW driver | |||
Interfaces | LAN (TCP/IP, 10BASE-T/100BASE-TX) | RS-232C (Max. 38.4 kbps, available as printer I/F) | EXT I/O (37-pin Handler interface) | Analog output (DC 0 V to 3.1 V) |
Power Supply | 100 to 240 V AC, 50 Hz/60 Hz, 35 VA maximum | |||
Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) | |||
Weight | 5.2 lbs (2.4 kg) |
Resistance Measurement Ranges | 3 mΩ(max. display: 3.1000 mΩ, resolution: 0.1 µΩ, measurement current: 100 mA) 30 mΩ(max. display: 31.000 mΩ, resolution: 1 µΩ, measurement current: 100 mA) 300 mΩ(max. display: 310.00 mΩ, resolution: 10 µΩ, measurement current: 10 mA) 3 Ω(max. display: 3.1000 Ω, resolution: 100 µΩ, measurement current: 1 mA) 30 Ω(max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 µA) 300 Ω(max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 µA) 3 kΩ(max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 µA) |
|||
Basic Accuracy | ±0.5% rdg ±10 dgt(3 mΩ range), ±0.5% rdg ±5 dgt(30 mΩ range or more) | |||
Measurement Frequency | 1 kHz ±0.2 Hz | |||
Measurement Method | AC four-terminal method | |||
Voltage Measurement Ranges | 6 V(max. display: 6.00000 V, resolution: 10 µV) 60 V(max. display: 60.0000 V, resolution: 100 µV) 100 V(max. display: 100.000 V, resolution: 1 mV) |
|||
Response Time | 10 ms | |||
Functions | Contact check, zero adjustment (±1000 counts), pulse measurement, comparator (Hi/ IN/ Lo), statistical calculations (max. 30,000), delay, average, panel saving/loading, memory storage, LabVIEW driver | |||
Interfaces | LAN (TCP/IP, 10BASE-T/100BASE-TX) | RS-232C (Max. 38.4 kbps, available as printer I/F) | EXT I/O (37-pin Handler interface) | Analog output (DC 0 V to 3.1 V) |
Power Supply | 100 to 240 V AC, 50 Hz/60 Hz, 35 VA maximum | |||
Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) | |||
Weight | 5.2 lbs (2.4 kg) |