Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Model: T130 | UPC: 095969599696

Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Model: T130 | UPC: 095969599696

Essential to the tool belt, this voltage and continuity electrical tester is quick and easy to use. Featuring a clear audible and vibrating voltage indicator, the tester allows you to check the presence of voltage before working on any circuit with complete confidence.

Essential to the tool belt, this voltage and continuity electrical tester is quick and easy to use. Featuring a clear audible and vibrating voltage indicator, the tester allows you to check the presence of voltage before working on any circuit with complete confidence.

Sale Price $161.84 USD
Regular Price $194.99 USD
Availability 4 to 5 Weeks
Quantity

Fluke T130 Offers

Features

  • LED indication Range: 12 to 690 V AC/DC
  • V display: multiple LED bargraph
  • Independent ELV indicator LED, indicates if >50 V AC / 120 V DC is present even in the event of no battery power or main circuit failure
  • CAT III 690 V / CAT IV 600 V
  • Rugged, double-insulated wire
  • Fixed impedance ~200 kΩ (~3.5 mA at 690 V)
  • Switchable load by 2 pushbuttons (30 mA at 230 V)
  • Vibration during load (when 2 switchable load pushbuttons are pushed)
  • Single-pole phase test (also operates with gloves)
  • Rotary field direction (also operates with gloves)
  • Continuity test and diode Test
  • Torch
  • Beeper for continuity/phase/aCV (switchable)
  • Slim metal probe tips (threaded base for included tip accessories)
  • Probe tip protector cap (secure storage for the docked probes)
  • 4 mm ∅ probe tip thickness extensions (for better fit in outlets)
  • 19 mm probe tip distance when docked
  • Probe tip sheath

Fluke T130 Specifications

LEDs
Voltage Range 12 V to 690 V AC/DC
Resolution ±12 V, 24 V, 50 V, 120 V, 230 V, 400 V, 690 V
Tolerance Complies with EN 61243-3:2014
Frequency Range 0 / 40 Hz to 400 Hz
Response Time ≤0.5 second
Auto Power On ≥12 V AC/DC
LCD
Voltage Range 6 to 690 V AC/DC
Resolution ±1 V
Tolerance ±(3% rdg + 5 digits)
Frequency Range 0/40 to 400 Hz
Response Time ≤1 second
Autopower On ≥6 V AC/DC
General and Environmental Specifications
Voltage Detection Automatic
Polarity Detection Full range
Range Detection Automatic
Internal Basic Load Impedance Peak Current Maximum 3.5 mA at 690 V 200 kΩ / Is <3.5 mA (no RCD tripping)
Operation Time 30 seconds
Recovery Time 240 seconds
Switchable Load ~7 kΩ
Peak Current: Is (load) = 150 mA
RCD Tripping: I~30 mA @ 230 V
Continuity Test 0 to 400 kΩ
Accuracy: nominal resistance + 50%
Test current: ≤5 µA
Single-Pole Phase Test 100 to 690 V AC
Rotary Field Indication Voltage Range (LEDs): 100 to 690 V (phase to earth)
Frequency Range: 50 to 60 Hz
Environmental Pollution degree: 2
Protection degree: IP64
Operating Temperature 5 to 113°F (-15 to 45 °C)
Storage Temperature - 40 to 140°F (-20 to 60 °C)
Humidity 85% RH maximum
Altitude 6561' (2000 m)
Vibration refer to EN61243-3
Power Supply 2 x 1.5 V Micro / LR03 / AAA
Power Consumption 50 mA maximum /~250 mW
Language Support Czech, Dutch, English, Finnish, French, German, Italian, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
Dimensions 10 x 3 x 1.3" (255 x 78 x 35 mm)
Weight 0.59 lbs (0.27 kg)
Safety EN61243-3:2014 Transporting goods: VBG 1, § 35
Overvoltage protection: 690 V AC/DC
Measurement category: CAT III 690 V, CAT IV 600 V

What's included with the Fluke T130

  • Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Webinar: Electrical Equipment Safety with Fluke


When safety is on top of mind, everyone benefits. Ensuring that your facility employs the best workplace practices, test tool standards, and ratings, and considers the dangers and causes of incidents will make for a safer work environment. Taking steps to improve these aspects will allow you to enjoy benefits, such as increased productivity and reduced assets-related and accident-related costs. Many tools can help you improve safety by testing, maintaining, monitoring, or troubleshooting live electrical equipment.

Click on a category to view a selection of compatible accessories with the Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Customer Reviews for the Fluke T130

Fluke T130 Offers

Features

  • LED indication Range: 12 to 690 V AC/DC
  • V display: multiple LED bargraph
  • Independent ELV indicator LED, indicates if >50 V AC / 120 V DC is present even in the event of no battery power or main circuit failure
  • CAT III 690 V / CAT IV 600 V
  • Rugged, double-insulated wire
  • Fixed impedance ~200 kΩ (~3.5 mA at 690 V)
  • Switchable load by 2 pushbuttons (30 mA at 230 V)
  • Vibration during load (when 2 switchable load pushbuttons are pushed)
  • Single-pole phase test (also operates with gloves)
  • Rotary field direction (also operates with gloves)
  • Continuity test and diode Test
  • Torch
  • Beeper for continuity/phase/aCV (switchable)
  • Slim metal probe tips (threaded base for included tip accessories)
  • Probe tip protector cap (secure storage for the docked probes)
  • 4 mm ∅ probe tip thickness extensions (for better fit in outlets)
  • 19 mm probe tip distance when docked
  • Probe tip sheath

Fluke T130 Specifications

LEDs
Voltage Range 12 V to 690 V AC/DC
Resolution ±12 V, 24 V, 50 V, 120 V, 230 V, 400 V, 690 V
Tolerance Complies with EN 61243-3:2014
Frequency Range 0 / 40 Hz to 400 Hz
Response Time ≤0.5 second
Auto Power On ≥12 V AC/DC
LCD
Voltage Range 6 to 690 V AC/DC
Resolution ±1 V
Tolerance ±(3% rdg + 5 digits)
Frequency Range 0/40 to 400 Hz
Response Time ≤1 second
Autopower On ≥6 V AC/DC
General and Environmental Specifications
Voltage Detection Automatic
Polarity Detection Full range
Range Detection Automatic
Internal Basic Load Impedance Peak Current Maximum 3.5 mA at 690 V 200 kΩ / Is <3.5 mA (no RCD tripping)
Operation Time 30 seconds
Recovery Time 240 seconds
Switchable Load ~7 kΩ
Peak Current: Is (load) = 150 mA
RCD Tripping: I~30 mA @ 230 V
Continuity Test 0 to 400 kΩ
Accuracy: nominal resistance + 50%
Test current: ≤5 µA
Single-Pole Phase Test 100 to 690 V AC
Rotary Field Indication Voltage Range (LEDs): 100 to 690 V (phase to earth)
Frequency Range: 50 to 60 Hz
Environmental Pollution degree: 2
Protection degree: IP64
Operating Temperature 5 to 113°F (-15 to 45 °C)
Storage Temperature - 40 to 140°F (-20 to 60 °C)
Humidity 85% RH maximum
Altitude 6561' (2000 m)
Vibration refer to EN61243-3
Power Supply 2 x 1.5 V Micro / LR03 / AAA
Power Consumption 50 mA maximum /~250 mW
Language Support Czech, Dutch, English, Finnish, French, German, Italian, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
Dimensions 10 x 3 x 1.3" (255 x 78 x 35 mm)
Weight 0.59 lbs (0.27 kg)
Safety EN61243-3:2014 Transporting goods: VBG 1, § 35
Overvoltage protection: 690 V AC/DC
Measurement category: CAT III 690 V, CAT IV 600 V

What's included with the Fluke T130

  • Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Webinar: Electrical Equipment Safety with Fluke


When safety is on top of mind, everyone benefits. Ensuring that your facility employs the best workplace practices, test tool standards, and ratings, and considers the dangers and causes of incidents will make for a safer work environment. Taking steps to improve these aspects will allow you to enjoy benefits, such as increased productivity and reduced assets-related and accident-related costs. Many tools can help you improve safety by testing, maintaining, monitoring, or troubleshooting live electrical equipment.

Click on a category to view a selection of compatible accessories with the Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke T130 Two-pole Voltage and Continuity Tester, 12 to 690 V AC/DC

Customer Reviews for the Fluke T130

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab