Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

Model: 1630-2 FC | Order No: 1630-2FC | UPC: 095969831185

Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

Model: 1630-2 FC | Order No: 1630-2FC | UPC: 095969831185

Fast and safe, this earth-ground clamp measures indoor/outdoor earth-ground resistance and ac leakage currents without disconnecting the earth-ground stake from the grounding system. In addition, this clamp features a heavy-duty clamp jaw that stays in alignment and calibration in industrial conditions.

Fast and safe, this earth-ground clamp measures indoor/outdoor earth-ground resistance and ac leakage currents without disconnecting the earth-ground stake from the grounding system. In addition, this clamp features a heavy-duty clamp jaw that stays in alignment and calibration in industrial conditions.

Your Price $2599.99 USD
Availability 3 in Stock
Quantity

Traceable In-House Calibration Certificate for your Fluke 1630-2FC Earth Ground Clamp

Traceable In-House Calibration Certificate for your Fluke 1630-2FC Earth Ground Clamp

Fluke 1630-2 FC Offers

Eliminate the hazardous and time-consuming process of disconnecting parallel grounds with this earth-ground clamp capable of stakeless measurement. Additionally, this clamp saves time by recording and storing up to 32,760 measured values in memory at the set logging interval.

Features

  • Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes
  • AC leakage current measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system–ideal for system troubleshooting
  • Rugged: Heavy-duty clamp jaw stays in alignment and calibration even in every day, on-the-job industrial environments
  • Alarm threshold: User-defined high/low alarm limits, for rapid measurement evaluation
  • Band-pass filter: Selectable band-pass filter function removes unwanted noise from the ac leakage current measurement

Logging measurements

  • The earth ground clamp saves time by automatically recording data at pre-set intervals
  • Saves up to 32,760 measurements in memory at the set logging interval
  • Saves time by recording and storing measured values

Wireless system

  • Connects the clamp with an app on your smartphone or tablet
  • You can save these measurements, and images to cloud storage and share with your team
  • Maximize uptime and make confident maintenance decisions with data you can trust and trace
  • Access baseline, historical and current measurements by asset
  • Share your measurement data using video calls and emails

Stakeless measurement

The clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes. With this test method, a two-process measurement is made around the earth ground wire or bus bar using the specially-designed jaw of the clamp. Auxiliary test stakes are not used at all. A known voltage is induced by the source in the clamp, and the current is measured by the sensor in the clamp. The tester automatically determines the earth loop resistance for this section of the earthing system.

Fluke 1630-2 FC Specifications

Maximum Voltage to Earth Ground 1000 V
Frequency Range 40 Hz to 1 kHz
Ingress Protection IEC/EN 60529: IP30 with jaw closed
LCD Digital reading: 9999 counts
Refresh rate: 4/s
Overload Indication OL
Display Reading Specification with Loop Resistance Standard Input: 0.474 Ω, Minimum: 0.417, Maximum: 0.531
Input: 0.5 Ω, Minimum: 0.443, Maximum: 0.558
Input: 10 Ω, Minimum: 9.55, Maximum: 10.45
Input: 100 Ω, Minimum: 96, Maximum: 104
Data Logging Capacity: Minimum of 32,760 measurements
Interval: 1 second to 59 minutes and 59 seconds
Wireless Radio Frequency range: 2412 to 2462 MHz
Output power: <10 mW
Radio frequency certification: FCC ID:T68-FBLE IC:6627A-FBLE
Safety General: IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
Measurement: IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current Clamp for Leakage Current Measurements IEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to Earth IEC/EN 61557-5
Effectiveness of The Protective Measures IEC/EN 61557-16: cutoff frequency 20 kHz (-3 dB)
Electromagnetic Compatibility (EMC) International: IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Conductor Size 1.57" (40 mm) approximately
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -4 to 140°F (-20 to 60°C)
Reference: 73°F ±9°F (23°C ±5°C)
Coefficient: 0.15% X (specified accuracy)/°C (<64.4°F or >82.4°F [<18°C or >28°C])
Operating Humidity Non condensing: <50°F (<10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C) (Non condensing)
Altitude Operating: 6561' (2000 m)
Storage: 39370' (12,000 m)
Battery Type: 4 x 1.5 V AA alkaline IEC/EN LR6
Life: More than 15 hours (In ground resistance measurement mode, with backlight turned off, and RF mode turned off)
Dimensions 11.1 x 4.1 x 1.9" (283 x 105 x 48 mm)
Weight 31 oz (880 g)
Click here for complete specifications on the Fluke 1630-2 FC

What's included with the Fluke 1630-2 FC

  • Earth Ground Clamp
  • Loop Resistance Standard
  • Hard Case
  • 4 x AA Batteries
  • Safety Information Guide
  • Quick Reference Guide
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

Customer Reviews for the Fluke 1630-2 FC

Fluke 1630-2 FC Offers

Eliminate the hazardous and time-consuming process of disconnecting parallel grounds with this earth-ground clamp capable of stakeless measurement. Additionally, this clamp saves time by recording and storing up to 32,760 measured values in memory at the set logging interval.

Features

  • Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes
  • AC leakage current measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system–ideal for system troubleshooting
  • Rugged: Heavy-duty clamp jaw stays in alignment and calibration even in every day, on-the-job industrial environments
  • Alarm threshold: User-defined high/low alarm limits, for rapid measurement evaluation
  • Band-pass filter: Selectable band-pass filter function removes unwanted noise from the ac leakage current measurement

Logging measurements

  • The earth ground clamp saves time by automatically recording data at pre-set intervals
  • Saves up to 32,760 measurements in memory at the set logging interval
  • Saves time by recording and storing measured values

Wireless system

  • Connects the clamp with an app on your smartphone or tablet
  • You can save these measurements, and images to cloud storage and share with your team
  • Maximize uptime and make confident maintenance decisions with data you can trust and trace
  • Access baseline, historical and current measurements by asset
  • Share your measurement data using video calls and emails

Stakeless measurement

The clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes. With this test method, a two-process measurement is made around the earth ground wire or bus bar using the specially-designed jaw of the clamp. Auxiliary test stakes are not used at all. A known voltage is induced by the source in the clamp, and the current is measured by the sensor in the clamp. The tester automatically determines the earth loop resistance for this section of the earthing system.

Fluke 1630-2 FC Specifications

Maximum Voltage to Earth Ground 1000 V
Frequency Range 40 Hz to 1 kHz
Ingress Protection IEC/EN 60529: IP30 with jaw closed
LCD Digital reading: 9999 counts
Refresh rate: 4/s
Overload Indication OL
Display Reading Specification with Loop Resistance Standard Input: 0.474 Ω, Minimum: 0.417, Maximum: 0.531
Input: 0.5 Ω, Minimum: 0.443, Maximum: 0.558
Input: 10 Ω, Minimum: 9.55, Maximum: 10.45
Input: 100 Ω, Minimum: 96, Maximum: 104
Data Logging Capacity: Minimum of 32,760 measurements
Interval: 1 second to 59 minutes and 59 seconds
Wireless Radio Frequency range: 2412 to 2462 MHz
Output power: <10 mW
Radio frequency certification: FCC ID:T68-FBLE IC:6627A-FBLE
Safety General: IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
Measurement: IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current Clamp for Leakage Current Measurements IEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to Earth IEC/EN 61557-5
Effectiveness of The Protective Measures IEC/EN 61557-16: cutoff frequency 20 kHz (-3 dB)
Electromagnetic Compatibility (EMC) International: IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Conductor Size 1.57" (40 mm) approximately
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -4 to 140°F (-20 to 60°C)
Reference: 73°F ±9°F (23°C ±5°C)
Coefficient: 0.15% X (specified accuracy)/°C (<64.4°F or >82.4°F [<18°C or >28°C])
Operating Humidity Non condensing: <50°F (<10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C) (Non condensing)
Altitude Operating: 6561' (2000 m)
Storage: 39370' (12,000 m)
Battery Type: 4 x 1.5 V AA alkaline IEC/EN LR6
Life: More than 15 hours (In ground resistance measurement mode, with backlight turned off, and RF mode turned off)
Dimensions 11.1 x 4.1 x 1.9" (283 x 105 x 48 mm)
Weight 31 oz (880 g)
Click here for complete specifications on the Fluke 1630-2 FC

What's included with the Fluke 1630-2 FC

  • Earth Ground Clamp
  • Loop Resistance Standard
  • Hard Case
  • 4 x AA Batteries
  • Safety Information Guide
  • Quick Reference Guide
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

Customer Reviews for the Fluke 1630-2 FC

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab