Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit

Model: 1625-2-KIT | UPC: 095969666879

Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit

Model: 1625-2-KIT | UPC: 095969666879

Rugged and reliable, this stakeless earth ground clamp is perfect for industrial environments. High-quality, the heavy-duty clamp jaw stays in alignment and calibration, and users can identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.

Rugged and reliable, this stakeless earth ground clamp is perfect for industrial environments. High-quality, the heavy-duty clamp jaw stays in alignment and calibration, and users can identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.

Your Price $5749.99 USD
Availability 6 to 7 Weeks
Quantity

Simpler, faster earth ground tests than ever before. With internal memory storage of up to 1500 records, users can have a faster setup made easy with the new color-coded wires that help eliminate mistakes.

Features

  • One-button measurement concept
  • 3- and 4-pole earth ground measurement
  • 4-pole soil resistivity testing
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Measuring frequency 128 Hz

Applications

  • Oil and gas
  • Mining/mineral and metal processing
  • Process manufacturing - chemical processing
  • Utilities
  • Manufacturing: machinery, instrumentation, and appliances

How to Get Faster Three-Phase Power Measurements with Fluke Clamp Meters

Complete three-phase voltage and current measurements 50% faster! We're confident in this because it's been tested at customer sites. The new clamp meters from Fluke (models 377 FC & 378 FC) feature FieldSense™ technology where voltage and current can be measured simultaneously with the clamp jaw. Meaning, these clamp meters can be used to make sequential line-to-ground measurements and current measurements that result in calculated line-to-line voltage measurements and phase rotation information.

In this application note, we walk you through the old versus the new way of doing phase-to-phase measurements along with step-by-step instructions on how to make these measurements.

Read the Application Note
How to Get Faster Three-Phase Power Measurements with Fluke Clamp Meters

Specifications

Temperature Range
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Temperature Coefficient ±0.1% of reading/°C <18°C >28°C
Error Intrinsic: Refers to the reference temperature range and is guaranteed for one year
Operating: Refers to the operating temperature range and is guaranteed for one year
Climatic Class C1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective Type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity) IEC61326-1: Portable
Quality System Developed, designed, and manufactured according to DIN ISO 9001
External Voltage V external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection >120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Time Typical six seconds
Maximum Overload 250 V rms (pertains to misuse)
Auxiliary Power 6 x 1.5 V Alkaline (type AA LR6)
Battery Life Span Typical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 3-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 4-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS + RES) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 3-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 4-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch Position RA 4-pole 2 clamps
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring Voltage Vm = 48 V ac
Measure Frequency 128 Hz
Noise Current (IEXT) Maximum IEXT = 10 A (ac) (RA <20 Ω)
General Specifications
Display 1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User Interface Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust Resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Dimensions 9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight 2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case
Click here for complete specifications on the Fluke 1625-2-KIT

What's included with the Fluke 1625-2-KIT

  • Fluke Tester
  • 2 x Test Leads
  • 4 x Earth Ground Stakes
  • 3 x Cable Reels with Wire
  • 2 x Clamps (One Inducing, One Sensing)
  • Carrying Case
  • Batteries
  • User's Manual

Click on a category to view a selection of compatible accessories with the Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit

Customer Reviews for the Fluke 1625-2-KIT

Simpler, faster earth ground tests than ever before. With internal memory storage of up to 1500 records, users can have a faster setup made easy with the new color-coded wires that help eliminate mistakes.

Features

  • One-button measurement concept
  • 3- and 4-pole earth ground measurement
  • 4-pole soil resistivity testing
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Measuring frequency 128 Hz

Applications

  • Oil and gas
  • Mining/mineral and metal processing
  • Process manufacturing - chemical processing
  • Utilities
  • Manufacturing: machinery, instrumentation, and appliances

How to Get Faster Three-Phase Power Measurements with Fluke Clamp Meters

Complete three-phase voltage and current measurements 50% faster! We're confident in this because it's been tested at customer sites. The new clamp meters from Fluke (models 377 FC & 378 FC) feature FieldSense™ technology where voltage and current can be measured simultaneously with the clamp jaw. Meaning, these clamp meters can be used to make sequential line-to-ground measurements and current measurements that result in calculated line-to-line voltage measurements and phase rotation information.

In this application note, we walk you through the old versus the new way of doing phase-to-phase measurements along with step-by-step instructions on how to make these measurements.

Read the Application Note
How to Get Faster Three-Phase Power Measurements with Fluke Clamp Meters

Specifications

Temperature Range
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Temperature Coefficient ±0.1% of reading/°C <18°C >28°C
Error Intrinsic: Refers to the reference temperature range and is guaranteed for one year
Operating: Refers to the operating temperature range and is guaranteed for one year
Climatic Class C1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective Type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity) IEC61326-1: Portable
Quality System Developed, designed, and manufactured according to DIN ISO 9001
External Voltage V external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection >120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Time Typical six seconds
Maximum Overload 250 V rms (pertains to misuse)
Auxiliary Power 6 x 1.5 V Alkaline (type AA LR6)
Battery Life Span Typical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 3-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 4-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS + RES) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 3-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 4-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch Position RA 4-pole 2 clamps
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring Voltage Vm = 48 V ac
Measure Frequency 128 Hz
Noise Current (IEXT) Maximum IEXT = 10 A (ac) (RA <20 Ω)
General Specifications
Display 1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User Interface Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust Resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Dimensions 9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight 2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case
Click here for complete specifications on the Fluke 1625-2-KIT

What's included with the Fluke 1625-2-KIT

  • Fluke Tester
  • 2 x Test Leads
  • 4 x Earth Ground Stakes
  • 3 x Cable Reels with Wire
  • 2 x Clamps (One Inducing, One Sensing)
  • Carrying Case
  • Batteries
  • User's Manual

Click on a category to view a selection of compatible accessories with the Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit

Customer Reviews for the Fluke 1625-2-KIT

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab