FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer DCT1000DC Series Dust Collector Timer Controllers

Dwyer DCT1000DC Series Dust Collector Timer Controllers

Model Selection

Dwyer DCT1006DC Dust Collector Timer Controller, 6 Channels, 10 to 35 VDC
DCT1006DC $345.44 USD
Was: $369.45
Availability:
1 to 2 Weeks
Dwyer DCT1010DC Dust Collector Timer Controller, 10 Channels, 10 to 35 VDC
DCT1010DC $413.00 USD
Was: $441.71
Availability:
5 Days
Dwyer DCT1022DC Dust Collector Timer Controller, 22 Channels, 10 to 35 VDC
DCT1022DC $513.32 USD
Was: $549.00
Availability:
5 Days

Model Selection

The DCT1000DC accepts 10-30 VDC power. The units modular design allows for use as a continuous cleaning control or on demand cleaning control using the optional DCP plug-in pressure module. A 4-20 mA process output is integral to the DCP pressure module, eliminating the need to purchase an expensive process transmitter.

The DCT1000DC accepts 10-30 VDC power. The units modular design allows for use as a continuous cleaning control or on demand cleaning control using the optional DCP plug-in pressure module. A 4-20 mA process output is integral to the DCP pressure module, eliminating the need to purchase an expensive process transmitter.

This product is a special order item which can’t be returned or cancelled.

Dwyer DCT1006DC Dust Collector Timer Controller, 6 Channels, 10 to 35 VDC
DCT1006DC $345.44 USD
Was: $369.45
Availability:
1 to 2 Weeks
Dwyer DCT1010DC Dust Collector Timer Controller, 10 Channels, 10 to 35 VDC
DCT1010DC $413.00 USD
Was: $441.71
Availability:
5 Days
Dwyer DCT1022DC Dust Collector Timer Controller, 22 Channels, 10 to 35 VDC
DCT1022DC $513.32 USD
Was: $549.00
Availability:
5 Days

Dwyer DCT1000DC Series Offers

Simplify your on-demand cleaning requirements with this dust collector timer controller. Relying on one timer board for on demand and continuous cleaning applications, it eliminates external devices such as pressure switches, relays and timers.

Features

  • 6, 10 and 22 output channel options
  • 10 to 30 VDC power requirement for low voltage applications
  • Units modular design allows for use as a continuous cleaning control or on demand cleaning control using the optional DCP plug-in pressure module
  • 4 to 20 mA process output is integral to the DCP pressure module, eliminating the need to purchase an expensive process transmitter
  • Standard mounting holes to other dust collector controllers for use in existing installations
  • Able to automatically detect any channel expander connected
  • Solenoid fault light notifies the operator when a solenoid valve fails to activate properly

Applications

  • Dust collection
  • Pneumatic conveying

Dwyer DCT1000DC Series Specifications

Output Channels 6, 10 and 22 channels
Power Requirements 10 to 30 VDC
Power Consumption 5 W
Solenoid Supply 3A maximum per channel
Fuse 3A at 250 VAC
Temperature Limits -40 to 140°F (-40 to 60°C)
Storage: -40 to 176°F (-40 to 80°C)
On-time 10 msec to 600 msec, 10 msec steps
Accuracy: ±10 msec
Off-time 1 second to 255 seconds, 1 second steps
Accuracy: ±1% of the value or ±50 msec, whichever is greater
Weight 1 lb (538.6 g)
Agency Approvals CE

What's included with the Dwyer DCT1000DC Series

  • Dwyer DCT1000DC Series Dust Collector Timer Controllers

Ask a question about Dwyer DCT1000DC Series Dust Collector Timer Controllers

Customer Reviews for the Dwyer DCT1000DC Series

Dwyer DCT1000DC Series Offers

Simplify your on-demand cleaning requirements with this dust collector timer controller. Relying on one timer board for on demand and continuous cleaning applications, it eliminates external devices such as pressure switches, relays and timers.

Features

  • 6, 10 and 22 output channel options
  • 10 to 30 VDC power requirement for low voltage applications
  • Units modular design allows for use as a continuous cleaning control or on demand cleaning control using the optional DCP plug-in pressure module
  • 4 to 20 mA process output is integral to the DCP pressure module, eliminating the need to purchase an expensive process transmitter
  • Standard mounting holes to other dust collector controllers for use in existing installations
  • Able to automatically detect any channel expander connected
  • Solenoid fault light notifies the operator when a solenoid valve fails to activate properly

Applications

  • Dust collection
  • Pneumatic conveying

Dwyer DCT1000DC Series Specifications

Output Channels 6, 10 and 22 channels
Power Requirements 10 to 30 VDC
Power Consumption 5 W
Solenoid Supply 3A maximum per channel
Fuse 3A at 250 VAC
Temperature Limits -40 to 140°F (-40 to 60°C)
Storage: -40 to 176°F (-40 to 80°C)
On-time 10 msec to 600 msec, 10 msec steps
Accuracy: ±10 msec
Off-time 1 second to 255 seconds, 1 second steps
Accuracy: ±1% of the value or ±50 msec, whichever is greater
Weight 1 lb (538.6 g)
Agency Approvals CE

What's included with the Dwyer DCT1000DC Series

  • Dwyer DCT1000DC Series Dust Collector Timer Controllers

Ask a question about Dwyer DCT1000DC Series Dust Collector Timer Controllers