Ergonomically designed to be comfortably held in one hand, this 3-in-1 handscope is compact and shockproof with a safety rating of IP54. In addition, this kit comes equipped with a 3.5" color screen with LED backlighting for displaying data, an AC probe with high voltage output, and a 10' lead with a BNC output.
Ergonomically designed to be comfortably held in one hand, this 3-in-1 handscope is compact and shockproof with a safety rating of IP54. In addition, this kit comes equipped with a 3.5" color screen with LED backlighting for displaying data, an AC probe with high voltage output, and a 10' lead with a BNC output.
Features
Oscilloscope Mode | |
Vertical Deflection | Bandwidth: 40 MHz Bandwidth Limiter: 1.5 MHz, 5 kHz Number of Channels: 2 totally isolated channels Input Impedance: 1 MΩ ±0.5%, approximately 17 pF Maximum Input Voltage: 600 V CAT III – Derating -20 dB per decade from 100 kHz Vertical Sensitivity: 5 mV to 200 V/div |
Horizontal Deflection | Sweep Speed: 25 ns/div to 200 s/div – roll mode from 100 ms to 200 s/div Horizontal Zoom: Zoom factor: x1, x2, x5 |
Triggering | Mod: Automatic, triggered, one-shot & triggered roll Typ: Edge, pulse width (20 ns to 20 s) Couplin: AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection Sensitiv: ≤1.2 divisions p-p up to 40 MHz |
Multimeter Mode | |
General Specifications | 2 channels, 8000-count display + min/max bargraph – Graphic recording of 2700 measurements (5 min to 1 month) |
Operating Modes | Absolute or relative display (absolute, deviation, ref, ref%) – Monitoring (instantaneous, min, max, Avg) |
AC, DC & AC+DC Voltages | Ranges from 600 mV to 600 V RMS, 800 mV to 800 V DC – accuracy for V DC ±1% reading+20D – 50 kHz bandwidth |
Resistance | Range from 80 Ω to 32 MΩ - accuracy ±2% reading + 10 D – 10 ms quick continuity test |
Capacitance | Ranges from 5 nF to 5 mF – basic accuracy ±2% reading + 10 D |
Other Measurements | Frequency, rotation speed, 3.3 V diode test, temperature measurement (with K-type thermocouple or infrared probe) |
Harmonic Analyzer Mode | |
Multi-Channel Analysis | 2 channels, 31 orders, fundamental frequency from 40 to 450 Hz |
Simultaneous Measurements | Total V RMS, THD, and selected order (% fundamental, phase, frequency, V RMS) |
Oscilloscope Mode | |
Vertical Deflection | Bandwidth: 40 MHz Bandwidth Limiter: 1.5 MHz, 5 kHz Number of Channels: 2 totally isolated channels Input Impedance: 1 MΩ ±0.5%, approximately 17 pF Maximum Input Voltage: 600 V CAT III – Derating -20 dB per decade from 100 kHz Vertical Sensitivity: 5 mV to 200 V/div |
Horizontal Deflection | Sweep Speed: 25 ns/div to 200 s/div – roll mode from 100 ms to 200 s/div Horizontal Zoom: Zoom factor: x1, x2, x5 |
Triggering | Mod: Automatic, triggered, one-shot & triggered roll Typ: Edge, pulse width (20 ns to 20 s) Couplin: AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection Sensitiv: ≤1.2 divisions p-p up to 40 MHz |
Multimeter Mode | |
General Specifications | 2 channels, 8000-count display + min/max bargraph – Graphic recording of 2700 measurements (5 min to 1 month) |
Operating Modes | Absolute or relative display (absolute, deviation, ref, ref%) – Monitoring (instantaneous, min, max, Avg) |
AC, DC & AC+DC Voltages | Ranges from 600 mV to 600 V RMS, 800 mV to 800 V DC – accuracy for V DC ±1% reading+20D – 50 kHz bandwidth |
Resistance | Range from 80 Ω to 32 MΩ - accuracy ±2% reading + 10 D – 10 ms quick continuity test |
Capacitance | Ranges from 5 nF to 5 mF – basic accuracy ±2% reading + 10 D |
Other Measurements | Frequency, rotation speed, 3.3 V diode test, temperature measurement (with K-type thermocouple or infrared probe) |
Harmonic Analyzer Mode | |
Multi-Channel Analysis | 2 channels, 31 orders, fundamental frequency from 40 to 450 Hz |
Simultaneous Measurements | Total V RMS, THD, and selected order (% fundamental, phase, frequency, V RMS) |